Sign Regulations in Mancos, Colorado

Mancos, Colorado has specific sign regulations covering 24 sign types across 6 zoning districts. Regulated sign types include Wall Sign, Awning or Canopy Sign, Marquee Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: March 6, 2025

Sign Regulation Overview for Mancos, Colorado

Sample Sign Requirements in Mancos

Sign TypeMax HeightMax AreaSetback
Freestanding Sign12 feet32 square feet
Wall Sign32 square feet
Wall Sign - Civic and Public UsesNot to exceed height of wallFront wall: 10%; other walls 5%

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for MancosFull Coverage

Sign Types Covered

24

  • Wall Sign
  • Awning or Canopy Sign
  • Marquee Sign
  • Projecting or Suspended Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Mancos

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Mancos, monument signs are limited to 12 feet. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Mancos, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Mancos, regulated sign types include Wall Sign, Awning or Canopy Sign, Marquee Sign, Projecting or Suspended Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Mancos vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Mancos are regulated with specific requirements for brightness, animation, and message duration. Mancos has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Mancos Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Mancos, Colorado sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Mancos, Colorado Sign Rules at a Glance

Mancos, Colorado regulates 24 sign types across 6 zoning districts. Projecting or Suspended Signs in the Mixed-Use, Commercial, and Industrial Districts zoning district are capped at Height of wall where attached tall, 20 square feet; max. width 4 ft., and 4 feet wide (Sec. Table 16-13.2). Most commercial signs in Mancos require a permit.

Detailed Sign Ordinance Requirements for Mancos, Colorado

Sign Rules by Zoning District in Mancos (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Agricultural Districts212 feet32 square feet
Residential Districts712 feet24 square feet
Mixed-Use, Commercial, and Industrial Districts1316 feet100 square feet
Corridor Mixed-Use Districts1130 feet150 square feet
Planned Unit Development District1Equivalent to district and use categoriesEquivalent to district and use categories
General Regulations For All Zones1Varies by type and districtVaries by type and district

Zone-by-Zone Sign Requirements in Mancos(sample of 3 of 6 zones)

Residential Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign - Civic and Public UsesNot to exceed height of wallFront wall: 10%; other walls 5%1 per frontageFront wall or other wallsUnlockTable 16-13.1
Wall Sign - Cottage Industry, Home Occ, or Home-Based BusinessNot to exceed height of wall4 square feet1Attached to wallUnlockTable 16-13.1
Wall Sign - Multifamily ComplexNot to exceed height of wall10%1 per complexAttached to wallUnlockTable 16-13.1
Wall Sign - Multifamily BuildingNot to exceed height of wall10%1 per buildingAttached to wallUnlockTable 16-13.1
Monument Sign - Civic and Public Use12 feet24 square feet1 per frontagePer frontageUnlockTable 16-13.1
Monument Sign - B&B12 feet16 square feet; 1 sign face only1 totalPer propertyUnlockTable 16-13.1
Monument Sign - Multifamily Building or Complex and Residential Subdivision12 feet24 square feet; 1 sign face only1 per entrancePer entranceUnlockTable 16-13.1

Mixed-Use, Commercial, and Industrial Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning or Canopy SignTop of vertical face of awning; 12" above canopyLesser of 35 square feet or 25% of total awning or canopy area1 per frontageAttached to awning or canopyUnlockTable 16-13.2
Marquee SignTop of vertical face of marquee where attached20 square feet1 per frontageAttached to marqueeUnlockTable 16-13.2
Projecting or Suspended SignHeight of wall where attached20 square feet; max. width 4 ft.4 feet1 per buildingAttached to buildingUnlockTable 16-13.2
Wall SignHeight of wall where attached25 square feet1 per tenantAttached to wallUnlockTable 16-13.2
Wall Sign - Multitenant BuildingHeight of wall where attachedBased on number of tenants1 multitenant sign with 1 s.f. of sign area per tenantAttached to wallUnlockTable 16-13.2
Wall Sign - Multifamily Building or ComplexHeight of wall where attached24 square feet; 1 sign face only1 per frontageAttached to wallUnlockTable 16-13.2
Window SignHeight of window where affixed25% of any individual window1 per window or window in doorAffixed to windowUnlockTable 16-13.2
Access Point Sign3 feet6 square feet2 per propertyPer propertyUnlockTable 16-13.3

Corridor Mixed-Use Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning or Canopy SignTop of vertical face of awning; 12" above canopyLesser of 35 square feet or 25% of total awning or canopy area1 per frontageAttached to awning or canopyUnlockTable 16-13.4
Marquee SignTop of vertical face of marquee where attached20 square feet1 per frontageAttached to marqueeUnlockTable 16-13.4
Projecting or Suspended SignHeight of wall where attached20 square feet; max. width 4 ft.4 feet1 per buildingAttached to buildingUnlockTable 16-13.4
Wall SignHeight of wall where attached25 square feet1 per tenantAttached to wallUnlockTable 16-13.4
Window SignHeight of window where affixed25% of any individual window1 per window or window in doorAffixed to windowUnlockTable 16-13.4
Access Point Sign3 feet6 square feet2 per propertyPer propertyUnlockTable 16-13.5
Freestanding Structural Canopy SignMay not extend above canopy12 square feet1 per frontageAttached to canopyUnlockTable 16-13.5
Highway Access Sign20 feet18 x 54 per business1 multi-business sign per highway intersectionPer highway intersectionUnlockTable 16-13.5

PermitPal covers all 6 zoning districts in Mancos — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Mancos — start free

Prohibited Signs in Mancos

  • Signs employing mercury vapor, low-pressure and high-pressure sodium and metal halide lighting, or otherwise not complying with the illumination requirements of Article 12, Outdoor Lighting
  • Internally lit signs
  • Off-premise signs
  • Flutter fly and similar types of signs that contain or consist of ribbon streamers, strings of light bulbs, spinners, or other similar moving devices
  • Sign walkers
  • Electronic message centers (EMCs)
  • Real time video projected on outdoor display screens, outdoor video projection screens and outdoor LED screens, or outdoor display screens of any type are prohibited for use as signs, including in windows
  • Signs emitting sound
  • Any sign or sign structure that is structurally unsafe, constitutes a hazard to safety or health because of inadequate maintenance or dilapidation, is not kept in good repair, or is capable of causing electrical shocks to persons likely to come in contact with it
  • Abandoned signs
  • Banners used as permanent signs
  • In the right-of-way or on other public property without approval of the Town
  • Placed on private property without the consent of the owner
  • Located in or overhanging a utility easement
  • On roofs, dormers, and balconies
  • Located in such a way as to deny an adjoining property owner visual access to an existing sign
  • Attached to a tree, whether on public or private property

Exempt Signs in Mancos

  • Window displays of merchandise or products
  • Art that does not include commercial speech
  • Products, merchandise or other materials which are offered for sale or used in conducting a business, when such products, merchandise, or materials are kept or stored in a location which is designed and commonly used for the storage of such products, merchandise or materials
  • Any feature of display that would otherwise be considered a sign, but that has been found by the Planning Commission to be an integral part of a building that contributes to the character of the building and surrounding area
  • Internal and integral signs not intended for view or readily legible from the public right-of-way or adjacent residential, public, or civic institutional districts or uses
  • Integral signs that are carved into stone, concrete, or similar material or made of metal or other permanent-type construction and made an integral part of the structure
  • Signs that do not exceed two (2) square feet per face or four (4) square feet in total surface area that are affixed to machines, equipment, fences, gates, walls, gasoline pumps/EV charging units, or utility cabinets
  • Signs or banners on fences and structures within an arena, Town park, recreational complex, or scoreboards for athletic fields, provided such signs or banners face inward to the arena, Town park, recreational complex, or athletic field
  • Non-commercial flags, crests, or banners that are sixty (60) square feet or less and are affixed to a permanent flagpole or building
  • Official public signs approved by a governmental or quasi-governmental body, Town department, or special district for structures used by the governmental organization and signs related to issues that the governmental organization has jurisdiction over
  • Signs and notices required to be maintained by law or governmental order, rule, or regulation, provided that the content and size of the sign does not exceed the requirements of such law, order, rule, or regulation
  • Seasonal decorations located on private property

Sign Plan & Submission Notes for Mancos

  • An applicant for PUD district approval may submit a signage plan to the planning commission for review and recommendation to alter the sign regulations which would otherwise be applicable to the Planned Unit Development district.
  • All signage plans shall be submitted with the PUD application and shall include, at a minimum, a drawing of all proposed signs, detailed information on each sign proposed, a site plan of the planned development district, a written explanation of the reasons for the request, and an analysis showing evidence of no net increase in total signage area.

Source: municode municipal code