Mead, Colorado has specific sign regulations covering 27 sign types across 7 zoning districts. Regulated sign types include Fascia Sign, Optional Storage Tank or Utility Cabinet or Pedestal Sign, Primary Detached Sign. Height restrictions apply. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Mead, Colorado

Sample Sign Requirements in Mead

Sign TypeMax HeightMax AreaSetback
Wall Sign (Single-family and duplex)2 SF
Window Sign1.5 SF per window
Primary Detached Sign6 ft32 SF12 ft. from building walls; 100 ft. from other primary detached signs; 1 ft. from front property lines plus additional setback for height above 4 ft; side and rear setback equal to sign height; subject to sight distance and utility easements

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for MeadPartial Coverage

Sign Types Covered

27

  • Fascia Sign
  • Optional Storage Tank or Utility Cabinet or Pedestal Sign
  • Primary Detached Sign
  • Site Sign (Temporary)
  • +2 more types

Zoning Districts

7

Different zoning districts with specific sign regulations

Data Includes

  • Height restrictions
  • Illumination rules

Official Resources for Mead

City WebsiteMunicipal Code5 permit application links available

Frequently Asked Questions

Sign height limits in Mead vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Mead, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Mead, regulated sign types include Fascia Sign, Optional Storage Tank or Utility Cabinet or Pedestal Sign, Primary Detached Sign, Site Sign (Temporary), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Mead vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Mead are regulated with specific requirements for brightness, animation, and message duration. Mead has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Mead Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Mead, Colorado sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Mead, Colorado Sign Rules at a Glance

Mead, Colorado regulates 27 sign types across 7 zoning districts. Primary Detached Signs in the Downtown Mixed-Use (DMU) zoning district are capped at 15 ft; 25 ft if on I-25 frontage; 15 ft + 5 ft if on Hwy 66 frontage tall and 1 SF per 2 LF of frontage for first 100 ft, then 1 SF per 4 LF; max 300 SF (multi-tenant, I-25); 200 SF (single-tenant, I-25); 175 SF (multi-tenant, Hwy 66); 125 SF (single-tenant, Hwy 66); 100 SF (otherwise), with a 12 ft from building walls, 100 ft from other primary detached signs, 1 ft from front property line plus additional setback for height above 4 ft, side/rear setback equal to sign height setback (Sec. Sec. 16-7-120, Table 7.12(1)).

Detailed Sign Ordinance Requirements for Mead, Colorado

Sign Rules by Zoning District in Mead (7 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential (RSF-E, RSF-1, RSF-4, RMF-8, RMF-14)1110 ft48 SF
Agricultural (AG)86 ft32 SF
Downtown Mixed-Use (DMU)1815 ft; 25 ft if on I-25 frontage; 15 ft + 5 ft if on Hwy 66 frontageLesser of 100 SF or 50% of width of front elevation x 4
Welker Corridor (west of I-25)1815 ft; 25 ft I-25; 20 ft Hwy 66Lesser of 100 SF or 50% width of front elevation x 4
Commercial (GC, HC)1915 ft; 25 ft I-25; 15 ft + 5 ft Hwy 66225 SF
Industrial (LI)1915 ft; 25 ft I-25; 15 ft + 5 ft Hwy 66225 SF
General Regulations For All Zones5Flagpole up to max building height of district32 SF (per flag)

Zone-by-Zone Sign Requirements in Mead(sample of 3 of 7 zones)

Downtown Mixed-Use (DMU)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Primary Detached Sign15 ft; 25 ft if on I-25 frontage; 15 ft + 5 ft if on Hwy 66 frontage1 SF per 2 LF of frontage for first 100 ft, then 1 SF per 4 LF; max 300 SF (multi-tenant, I-25); 200 SF (single-tenant, I-25); 175 SF (multi-tenant, Hwy 66); 125 SF (single-tenant, Hwy 66); 100 SF (otherwise)12 ft from building walls, 100 ft from other primary detached signs, 1 ft from front property line plus additional setback for height above 4 ft, side/rear setback equal to sign height1 per parcelPrimary detachedUnlockSec. 16-7-120, Table 7.12(1)
Secondary Detached Sign4 ft6 SF1 ft from property lines; 2 ft from sidewalk/pavement1 per vehicular entrance1 per vehicular entranceUnlockSec. 16-7-120, Table 7.12(1)
Site Sign (Temporary)6 ft32 SF2 ft from all property lines1 per parcel1 per parcelUnlockSec. 16-7-140, Table 7.14
Subdivision Under Development (SUD) Sign (Temporary)6 ft32 SF2 ft1 per entrance plus 1At each entrance plus one additionalUnlockSec. 16-7-140, Table 7.14
Yard Sign (Temporary)3 ft6 SFSame as residentialWhere allowed, same as residentialUnlockSec. 16-7-140, Table 7.14
Swing Sign (Temporary)5 ft5 SF, including ridersSame as residentialWhere allowed, same as residentialUnlockSec. 16-7-140, Table 7.14
Sidewalk Sign (Temporary)4 ft6 SF1 per primary building entranceWithin 10 ft of a principal building entrance; must leave 4 ft clear sidewalk widthUnlockSec. 16-7-140, Table 7.14
Banner (Temporary)4 ft or any location if affixed to fence/retaining wall32 SF1 per street frontageAffixed to fence, handrail, or retaining wall; or stretched between postsUnlockSec. 16-7-140, Table 7.14

Commercial (GC, HC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Primary Detached Sign15 ft; 25 ft I-25; 15 ft + 5 ft Hwy 661 SF per 2 LF frontage for first 100 ft, then 1 SF per 4 LF, max 300/200/175/125/100 SF (see Table 7.12(1))12 ft from walls, 100 ft from other primary detached signs, 1 ft from front property line (+1 ft per 2 ft above 4 ft), side/rear = sign height1 per frontagePrimary detachedUnlockSec. 16-7-120, Table 7.12(1)
Secondary Detached Sign4 ft8 SF1 ft from property lines, 2 ft from pavement/sidewalk1 per vehicular entrance1 per vehicular entranceUnlockSec. 16-7-120, Table 7.12(1)
Site Sign (Temporary)6 ft32 SF2 ft from all property lines1 per frontage1 per frontageUnlockSec. 16-7-140, Table 7.14
Subdivision Under Development (SUD) Sign (Temporary)10 ft48 SF2 ft from front, 10 ft from all other property lines, 10 ft apart for SUD signs1 per entrance1 per entranceUnlockSec. 16-7-140, Table 7.14
Yard Sign (Temporary)3 ft6 SF2 ft from all property lines, 2 ft apart2 per vehicular accessSee residential for other usesUnlockSec. 16-7-140, Table 7.14
Swing Sign (Temporary)5 ft5 SF including ridersSame as residentialSame as residentialUnlockSec. 16-7-140, Table 7.14
Sidewalk Sign (Temporary)4 ft6 SF1 per primary building entranceWithin 10 ft of building entrance, leaves 4 ft clear sidewalkUnlockSec. 16-7-140, Table 7.14
Inflatable Sign (Temporary)15 ft225 SF5 ft from all property lines1 per parcel1 per parcel (never with rooftop inflatable)UnlockSec. 16-7-140, Table 7.14 and 7.13(3)

Industrial (LI)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Primary Detached Sign15 ft; 25 ft I-25; 15 ft + 5 ft Hwy 661 SF per 2 LF frontage for first 100 ft, then 1 SF per 4 LF, max 300/200/175/125/100 SF (see Table 7.12(1))12 ft from walls, 100 ft from other primary detached signs, 1 ft from front property line (+1 ft per 2 ft above 4 ft), side/rear = sign height1 per frontagePrimary detachedUnlockSec. 16-7-120, Table 7.12(1)
Secondary Detached Sign4 ft8 SF1 ft from property lines, 2 ft from pavement/sidewalk1 per vehicular entrance1 per vehicular entranceUnlockSec. 16-7-120, Table 7.12(1)
Site Sign (Temporary)6 ft32 SF2 ft from all property lines1 per frontage1 per frontageUnlockSec. 16-7-140, Table 7.14
Subdivision Under Development (SUD) Sign (Temporary)10 ft48 SF2 ft from front, 10 ft from all other property lines, 10 ft apart for SUD signs1 per entrance1 per entranceUnlockSec. 16-7-140, Table 7.14
Yard Sign (Temporary)3 ft6 SF2 ft from all property lines, 2 ft apart2 per vehicular accessSee residential for other usesUnlockSec. 16-7-140, Table 7.14
Swing Sign (Temporary)5 ft5 SF including ridersSame as residentialSame as residentialUnlockSec. 16-7-140, Table 7.14
Sidewalk Sign (Temporary)4 ft6 SF1 per primary building entranceWithin 10 ft of building entrance, leaves 4 ft clear sidewalkUnlockSec. 16-7-140, Table 7.14
Inflatable Sign (Temporary)15 ft225 SF5 ft from all property lines1 per parcel1 per parcel (never with rooftop inflatable)UnlockSec. 16-7-140, Table 7.14 and 7.13(3)

PermitPal covers all 7 zoning districts in Mead — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 7 zones for Mead — start free

Prohibited Signs in Mead

  • Animated or moving signs, including any moving, swinging, rotating, flashing, blinking, scintillating, fluctuating, or otherwise animated light, except as specifically permitted in Section 16-7-90, Message centers, with limited exception for a single, vertical, striped cylindrical pole in the DMU zoning district.
  • Portable signs, except as specifically permitted in Part 4, Standards for Temporary Signs.
  • Abandoned signs.
  • Awnings or fascias that are backlit or made of plastic.
  • Cardboard, card stock, or paper, except when laminated or used as a window sign.
  • Feather flags.
  • Flags, banners, or comparable elements designed to move in the wind when attached to another sign type (e.g., flags may be attached to flagpoles but not to monument signs).
  • Flashing lights, except as part of holiday displays.
  • Motor vehicles displaying signs, unless vehicles are operational, properly registered, regularly used as vehicles, and the signage does not interfere with their operation or cover windows, and vehicles are legally parked.
  • Semi trailers, shipping containers, or portable storage units displaying signs unless the vehicle/unit is used for its primary purpose, is structurally sound, registered (if applicable), the sign is incidental to the primary use, and the unit is parked in a designated loading area or construction site.
  • Stacked products such as tires, soft drink cases, bagged soil or mulch used as signs.
  • Spinning or moving parts, except for the limited exception of a single, striped cylindrical pole as a projecting sign in the DMU zoning district.
  • Unshielded bare light bulbs larger than C9 format or brighter than 50 lumens per bulb (neon tubing is not considered a bare light bulb).
  • Materials with a high degree of specular reflectivity, such as polished metal, installed in a manner that creates substantial glare, except retroreflective materials that comply with MUTCD.
  • Obstruction of building ingress or egress including doors, egress windows, fire escapes.
  • Obstruction of equipment or structures for public safety, building operations, or utility service (e.g., standpipes, fire hydrants, vents, meters).
  • Obstruction of any required sight distance triangle as defined by the approved Town engineering/design standards.
  • Posting, installing, or mounting signs on trees or shrubs.
  • Posting or mounting signs to any utility pole or light pole unless the sign is a banner or flag not more than 10 square feet in area, has consent from the pole owner, is properly mounted, is at proper clearance, and meets additional requirements.
  • Posting or mounting signs to utility cabinets or pedestals, except exempt signs by or with consent of the owner.
  • Signs in or over public rights-of-way except those specifically allowed (e.g., posted by government, for authorized work, on transit shelters, or under revocable agreement).
  • Signs within site distance triangle restrictions as specified in Town design standards.
  • Signs located with less horizontal or vertical clearance from authorized communication or electrical power lines than required by state law.
  • Wall signs located within six inches of architectural features or within twelve inches from building corners, cornice, or eave lines or ground planes, except certain wrap-around signs at corners.
  • Fascia signs installed in locations that cover decorative fascias.
  • Content prohibitions: text or graphics of indecent/immoral nature harmful to minors by law, unlawful activity, obscenity, fighting words, defamation, incitement, true threats, or presenting clear and present danger due to traffic sign confusion or false public safety information.

Exempt Signs in Mead

  • Public signs posted by the Town or another entity on behalf of the Town on Town-controlled property or by governmental or quasi-municipal entities not subject to Town jurisdiction on their property.
  • Signs required by law or regulation, including signs in furtherance of a public duty or function (e.g., traffic controls, street signs), to give legal notice (e.g., notice of pending action), to comply with building codes (e.g., address numbers), or other laws or regulations (e.g., Colorado Oil and Gas Conservation Commission Rule 210).
  • Small signs affixed to a building or structure not exceeding 2 square feet in sign area (one per elevation visible from public right-of-way or neighboring property).
  • Small signs less than 0.75 square foot affixed to doors, machines, equipment, fences, gates, walls, gasoline pumps, public telephones, or utility cabinets, provided the aggregate area within 12 feet does not exceed 3 square feet.
  • One optional residential wall sign, painted on, applied to, or affixed to a residential building front elevation, not exceeding 5 square feet.
  • Optional storage tank and utility cabinet/pedestal signs painted on or applied to the surface of above-ground storage tanks, utility cabinets, or pedestals that are currently in use for their primary purpose.
  • Flags hanging from building-mounted or ground-mounted flagpoles, with a maximum of three per lot, provided no flag exceeds 32 square feet and no flagpole exceeds maximum building height for the zoning district.
  • Holiday decorations and signs clearly incidental, customary, and commonly associated with a holiday.
  • Interior signs not visible from residential lots, abutting property, or public rights-of-way.
  • Temporary signs in compliance with applicable requirements of Part 4, except for site signs and Subdivision Under Development (SUD) signs.
  • Exempt signs as defined above are exempt from sign permit requirements but may still require building or related permits if subject to building or electrical code.

Sign Plan & Submission Notes for Mead

  • A sign permit is required prior to erection, installation, or substantial modification of any sign that is not an exempt sign as defined in Sec. 16-7-50(5).
  • Application for a sign permit must be made to the Planning Department and include a scaled drawing/specifications. (Sec. 16-7-160(2))
  • A Sign Design Program is an alternative process for unified signage throughout a development and acts as a master sign plan for an entire development. It must be reviewed and approved by Planning Commission at a public hearing. (Sec. 16-7-170)
  • Sign Design Program applications require plans showing boundaries, building elevations, sign dimensions and locations, materials/colors, proposed illumination, design theme, and demonstration of improved aesthetics and reduced clutter. Approval may allow deviation from some standards with findings.
  • Prohibited signs and elements enumerated in Section 16-7-70 cannot be included in a Sign Design Program.
  • Planning Commission may attach conditions unrelated to sign content or viewpoint to Sign Design Program approvals.
  • Sign Design Program approvals have a term of three years, and may be extended if tied to concurrent development approval (Sec. 16-7-170(10)).
  • Sign Design Programs may be amended by the same public process as initial approval.
  • Sign permits are not required for exempt signs listed in Sec. 16-7-50(5), but such signs must still comply with other requirements of the ordinance.
  • Site and SUD temporary signs require a permit as per Table 7.14 and notes in Part 4; permits for such signs must be renewed annually to extend display duration.

Source: municode municipal code