Sign Regulations in Davie, Florida

Davie, Florida has specific sign regulations covering 29 sign types across 11 zoning districts. Regulated sign types include Flag, Building Sign, Building Address Number Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 27, 2026

Sign Regulation Overview for Davie, Florida

Sample Sign Requirements in Davie

Sign TypeMax HeightMax AreaSetback
Ground-mounted Sign (Single-family community common area, Multi-family residential)6 ft.32 sq. ft. per parcel
Noncommercial Ground-mounted Sign (Temporary) (Single-family residential lot)6 ft.8 sq. ft. per parcel (Sec. 12-237(C)), up to 16 sq. ft./acre (Sec. 12-238(A)); per sign: 4 sq. ft.
Noncommercial Ground-mounted Sign (Temporary) (Single-family community common area)6 ft.16 sq. ft./acre; per sign: 4 sq. ft.

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for DavieFull Coverage

Sign Types Covered

29

  • Flag
  • Building Sign
  • Building Address Number Sign
  • Ground-mounted Sign
  • +2 more types

Zoning Districts

11

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Davie

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

Sign height limits in Davie vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Davie, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Davie, regulated sign types include Flag, Building Sign, Building Address Number Sign, Ground-mounted Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Davie vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Davie are regulated with specific requirements for brightness, animation, and message duration. Davie has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Davie Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Davie, Florida sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Davie, Florida Sign Rules at a Glance

Davie, Florida regulates 29 sign types across 11 zoning districts. Flags in the Residential zoning districts zoning district are capped at Flag pole not to exceed zoning district height tall and Max flag up to 20% of pole height (see table Sec. 12-237(G)), with a Setback from property line a distance equal to height of pole setback (Sec. Sec. 12-237(G)). Most commercial signs in Davie require a permit.

Detailed Sign Ordinance Requirements for Davie, Florida

Sign Rules by Zoning District in Davie (11 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential zoning districts96 ft.32 sq. ft. per parcel
Nonresidential zoning districts, Commercial zoning districts, Industrial zoning districts, Institutional zoning districts10up to 70 ft. (or district height limit, whichever less)max flag size per height table (up to 216 sq. ft. for 70 ft. pole, see Sec. 12-237(G)); max flag area is 20% of pole height.
Mixed use zoning districts4up to 70 ft. (or district height limit, whichever less)See sign area allocation table: up to 160 sq. ft. depending on frontage (Sec. 12-237(H)).
Western Theme District26 ft.32 sq. ft.
Scenic Corridor14.5 ft.24 sq. ft.
Griffin Road Corridor District1
Regional Activity Center1
RAC-AV zoning district1200 sq. ft. per sign face
RAC-TC zoning districts115 ft.200 sq. ft. per sign face
Shopping centers (Nonresidential zoning districts - Shopping Centers), Office parks (Nonresidential zoning districts - Office Parks), Industrial parks (Nonresidential zoning districts - Industrial Parks)1
General Regulations For All Zones415 ft.6 sq. ft.

Zone-by-Zone Sign Requirements in Davie(sample of 3 of 11 zones)

Residential zoning districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground-mounted Sign (Single-family residential lot)None allowedOn parcelUnlockSec. 12-237(A), Sec. 12-241
Ground-mounted Sign (Single-family community common area, Multi-family residential)6 ft.32 sq. ft. per parcel2 per approved vehicle access pointAt vehicle access pointsUnlockSec. 12-237(A), Table, Sec. 12-241
Building Sign (Single-family community common area, Multi-family residential)On building facadeUnlockSec. 12-237(A), Table, Sec. 12-241
Noncommercial Ground-mounted Sign (Temporary) (Single-family residential lot)6 ft.8 sq. ft. per parcel (Sec. 12-237(C)), up to 16 sq. ft./acre (Sec. 12-238(A)); per sign: 4 sq. ft.On parcelUnlockSec. 12-238(A), Sec. 12-237(C), Sec. 12-241
Noncommercial Ground-mounted Sign (Temporary) (Single-family community common area)6 ft.16 sq. ft./acre; per sign: 4 sq. ft.On parcelUnlockSec. 12-238(A)
Noncommercial Ground-mounted Sign (Temporary) (Multi-family residential)6 ft.16 sq. ft./acre; per sign: 8 sq. ft.On parcelUnlockSec. 12-238(A)
FlagFlag pole not to exceed zoning district heightMax flag up to 20% of pole height (see table Sec. 12-237(G))Setback from property line a distance equal to height of pole1 pole/acre, max 2 flags per poleOn flagpoleUnlockSec. 12-237(G)
Off-premise Directional Sign (Residential Event)3 ft.4 sq. ft. per sign3 per eventWithin 2,500 ft of event parcel in landscaped swale/median of public right-of-wayUnlockSec. 12-240(F)

Nonresidential zoning districts, Commercial zoning districts, Industrial zoning districts, Institutional zoning districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground-mounted Sign (Single-tenant Commercial/Industrial/Institutional)15 ft. (20 ft. along State Road 84)See sign area allocation table: up to 160 sq. ft. depending on frontage (Sec. 12-237(H)).Setback from property line equals sign height.2 per approved vehicle access pointAt approved vehicular access pointsUnlockSec. 12-237(B), (H), 12-241, 12-239(C)
Ground-mounted Sign (Multi-tenant Commercial/Industrial/Institutional)15 ft. (20 ft. along State Road 84)See sign area allocation table: up to 160 sq. ft. depending on frontage (Sec. 12-237(H)).Setback from property line equals sign height.2 per approved vehicle access pointAt approved vehicular access pointsUnlockSec. 12-237(B), (H), 12-241, 12-239(C)
Noncommercial Ground-mounted Sign (Temporary) (Single/Multi-tenant Commercial/Industrial/Institutional)6 ft.16 sq. ft. per acre; per sign: 8 sq. ft.On parcelUnlockSec. 12-238(A),(D)
Banner Sign (Temporary)10% of allocated building sign area, maximum per sign: 0.5 sq. ft. per foot of building facade or 32 sq. ft., whichever is less.Must be attached to solid wall or building elevationUnlockSec. 12-240(B), Sec. 12-241
Window Sign (Temporary)Up to 10% of window area, no sign >20 sq. ft.20 sq. ft.On or behind windowUnlockSec. 12-240(C), Sec. 12-241
A-frame (Sandwich Board) Sign (Temporary)8 sq. ft. per signOn paved walkways on private property, within 100 ft of main entranceUnlockSec. 12-240(D), Sec. 12-241
Public/Institutional Banner Sign (on Fence)32 sq. ft.On fence, institutional uses onlyUnlockSec. 12-240(E)
Flagup to 70 ft. (or district height limit, whichever less)max flag size per height table (up to 216 sq. ft. for 70 ft. pole, see Sec. 12-237(G)); max flag area is 20% of pole height.Setback from all property boundaries equal to height of pole.1 pole/acre, max 2 flags/poleOn flagpoleUnlockSec. 12-237(G)

Mixed use zoning districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground-mounted Sign (Single-tenant or Multi-tenant)15 ft. (20 ft. along State Road 84)See sign area allocation table: up to 160 sq. ft. depending on frontage (Sec. 12-237(H)).Setback from property line equals sign height.2 per approved vehicle access pointAt approved vehicular access pointsUnlockSec. 12-237(B), (H), Sec. 12-241
Building SignOn building facadesUnlockSec. 12-237(B), Sec. 12-241
Noncommercial Ground-mounted Sign (Temporary)6 ft.16 sq. ft. per acre; per sign: 8 sq. ft.On parcelUnlockSec. 12-238(A), Sec. 12-241
Flagup to 70 ft. (or district height limit, whichever less)max flag size per height table; max flag area is 20% of pole height.Setback from all property boundaries equal to height of pole.1 pole/acre, max 2 flags/poleOn flagpoleUnlockSec. 12-237(G)

PermitPal covers all 11 zoning districts in Davie — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 11 zones for Davie — start free

Prohibited Signs in Davie

  • Signs that do not comply with the provisions of this division.
  • Animated signs.
  • Signs that may be confused with a traffic control device.
  • Signs painted directly onto a wall or other building surface, except as otherwise provided in section 12-239.
  • Signs painted or mounted upon rocks or trees.
  • Roof signs.
  • Horizontal rooftop signs.
  • Projected signs.
  • Searchlights.
  • Portable signs.
  • Vehicle signs.
  • Off premises signs except as otherwise provided in section 12-244.
  • Changeable copy signs.
  • Balloon signs and inflatable signs, except when located on the roof of a building for a maximum of sixty (60) days after issuance of a business tax receipt for a new business.
  • No sign of any character, including any sign advertising the exact nature and kind of business conducted on the premises, shall be permitted for the exhibition, by posting, painting or in any other manner displaying, of any statement, word, character or illustration of any obscene, indecent or immoral nature.
  • Signs that obstruct any window, door, fire escape, stairway, ladder or opening intended to provide light, air, ingress or egress for any building as required by law or as intended in the original design of the building.
  • Signs attached to a stand pipe or similar apparatus intended for public safety.
  • Signs which may obscure or interfere with the approved architectural elements of a building; for example, a sign shall not extend across windows, decorative stucco bands, arches, columns, cornices or similar architecturally distinct features.
  • Signs located within a private right-of-way.
  • Signs located within a public right-of-way.
  • Signs located within lands owned by a governmental water management entity, except as provided in section 12-243.
  • Signs located on or within public property except as provided in section 12-243.

Exempt Signs in Davie

  • Signs and sign structures erected or required to be erected by a governmental agency.
  • Flags otherwise meeting the requirements of section 12-237.
  • Change of copy on a lawfully established sign which is otherwise in compliance and does not involve changes in lighting, dimensions, or sign cabinets, except for signs in special districts governed by section 12-239(A).
  • Temporary signs otherwise meeting the standards of this division.
  • A-frame signs otherwise meeting the standards of this division.
  • Window signs otherwise meeting the standards of this division.
  • Signs placed on bus benches and bus shelters pursuant to a town franchise agreement.
  • Farm signs, to the extent exempt from municipal regulation pursuant to Sec. 604.50, Florida Statutes.
  • Signs associated with the retail sale of gasoline, to the extent that municipal regulation is preempted by Sec. 553.79(20)(a).
  • If a sign displaying commercial content is exempt from permitting, a sign of same physical characteristics displaying noncommercial content is also exempt.

Sign Plan & Submission Notes for Davie

  • Applications for sign permits must include drawings and specifications clearly indicating location, type of materials, construction, illumination, and sign copy; applications are reviewed for completeness and compliance.
  • Each shopping center, office park, and industrial park is encouraged to have a comprehensive sign plan to ensure tenant compatibility (as approved by the town).
  • Within shopping centers, office parks, and industrial parks, all building signs should utilize a consistent form of lighting/illumination throughout the development, as set forth in section 12-241.
  • Sign plans, including uniform sign plans and planned development design standards, may impose stricter or differing requirements, which shall control if more restrictive.
  • A variance to sign provisions may be requested from the town council via the procedures set forth in section 12-309 of the Town Code.
  • For internal message boards on parcels within certain zoning districts (RAC-AV), more than two internal message boards require a consistent design theme as adopted in the Master Site Plan and Design Standards required by section 12-32.417.

Source: municode municipal code