Sign Regulations in Miami Gardens, Florida
Miami Gardens, Florida has specific sign regulations covering 34 sign types across 4 zoning districts. Regulated sign types include Monument Sign (PAMA frontage on principal/minor arterial), Monument Sign (Collector and all other ROW), Temporary Signs – Residential Categories. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 19, 2026
Sign Regulation Overview for Miami Gardens, Florida
Sample Sign Requirements in Miami Gardens
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Monument Sign (PAMA frontage on principal/minor arterial) | 10 ft | 65 sq ft per sign (total 130 sq ft if 2 signs allowed) | Min 7 ft from all property lines or as needed to clear sight triangle; oriented 45°–90° to ROW |
| Monument Sign (Collector and all other ROW) | 6 ft | 54 sq ft per sign (total up to 108 sq ft if 2 signs allowed on sites with >500 ft frontage) | Min 7 ft from property lines; spacing and sight triangle per Sec. 34-657(2) |
| Wall Sign (PAMA frontage on principal/minor arterial) | May not extend above roofline; if parapet projects above roof, may not extend above top of parapet | Variable per formula | N/A (mounted to building; projection ≤12 inches) |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
34
- Monument Sign (PAMA frontage on principal/minor arterial)
- Monument Sign (Collector and all other ROW)
- Temporary Signs – Residential Categories
- Wall Sign (PAMA frontage on principal/minor arterial)
- +2 more types
Zoning Districts
4
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Miami Gardens
Other Cities in Florida
Frequently Asked Questions
In Miami Gardens, wall signs can be up to May not extend above roofline; if parapet projects above roof, may not extend above top of parapet and monument signs are limited to 10 ft. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.
To get a sign permit in Miami Gardens, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Miami Gardens, regulated sign types include Monument Sign (PAMA frontage on principal/minor arterial), Monument Sign (Collector and all other ROW), Temporary Signs – Residential Categories, Wall Sign (PAMA frontage on principal/minor arterial), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
In Miami Gardens, monument signs typically require a Min 7 ft from all property lines or as needed to clear sight triangle; oriented 45°–90° to ROW setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.
Digital and LED signs in Miami Gardens are regulated with specific requirements for brightness, animation, and message duration. Miami Gardens has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Miami Gardens Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Miami Gardens, Florida sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Miami Gardens, Florida Sign Rules at a Glance
Miami Gardens, Florida regulates 34 sign types across 4 zoning districts. Monument Sign (PAMA frontage on principal/minor arterial)s in the General Regulations For All Zones zoning district are capped at 10 ft tall, 65 sq ft per sign (total 130 sq ft if 2 signs allowed), and Width shall not exceed 10 ft per general proportion rules (1:1.5 height:width ratio) wide, with a Min 7 ft from all property lines or as needed to clear sight triangle; oriented 45°–90° to ROW setback (Sec. Sec. 34-658(1)(a)-(c); Sec. 34-657(2)(a)-(m) incl. m(1)-(9) (design, landscaping, illumination, setback, spacing, proportion, location, copy; changeable copy standards)). Most commercial signs in Miami Gardens require a permit.
Detailed Sign Ordinance Requirements for Miami Gardens, Florida
Sign Rules by Zoning District in Miami Gardens (4 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 23 | Ground pole height ≤30 ft or ≤10 ft above roofline of primary building, whichever is less | Total sign area (changeable + poster boxes/frames) ≤200 sq ft | — |
| Single-Family Dwelling Residential District (R-1) | 3 | Construction ≤10 ft; Noncommercial ≤8 ft; Residential real estate ≤5 ft; ‘Open house’ ≤2 ft | ≤24 sq ft | — |
| Two-Family Dwelling Residential District (R-2) | 3 | Construction ≤10 ft; Noncommercial ≤8 ft; Residential real estate ≤5 ft; ‘Open house’ ≤2 ft | ≤24 sq ft | — |
| Multiple-Family Dwelling Residential District (R-15), Multiple-Family Dwelling Residential District (R-25), Multiple-Family Dwelling Residential District (R-50), Neighborhood Commercial District (NC), Planned Corridor Development District (PCD), Light Industrial District (I-1), Heavy Industrial District (I-2), Planned Development District (PD), Agricultural and Utilities District (AU), Office District (OF), Government Properties District (GP), Entertainment Overlay District (EO), Business Transitional Overlay (BTO), Performance Arts, Civic and Entertainment Overlay District (PACE), Innovation Overlay District (INN) | 8 | Pole ≤30 ft or ≤10 ft above roofline (whichever less) | 65 sq ft per sign (total 130 sq ft if 2 signs) | — |
Zone-by-Zone Sign Requirements in Miami Gardens(sample of 3 of 4 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Monument Sign (PAMA frontage on principal/minor arterial) | 10 ft | 65 sq ft per sign (total 130 sq ft if 2 signs allowed) | Width shall not exceed 10 ft per general proportion rules (1:1.5 height:width ratio) | Min 7 ft from all property lines or as needed to clear sight triangle; oriented 45°–90° to ROW | 1 sign if ≥50 ft frontage; 0 if <50 ft frontage; 2 signs if two ≥50-ft frontages or ≥500 ft frontage on one ROW (max 2 total) | On parcels fronting a principal or minor arterial; oriented 45°–90° to abutting ROW; outside sight distance triangle; base 80% contact with ground; landscape bed at base. | — | Unlock | Sec. 34-658(1)(a)-(c); Sec. 34-657(2)(a)-(m) incl. m(1)-(9) (design, landscaping, illumination, setback, spacing, proportion, location, copy; changeable copy standards) |
| Monument Sign (Collector and all other ROW) | 6 ft | 54 sq ft per sign (total up to 108 sq ft if 2 signs allowed on sites with >500 ft frontage) | Width shall not exceed 10 ft per general proportion rules (1:1.5 height:width ratio) | Min 7 ft from property lines; spacing and sight triangle per Sec. 34-657(2) | 1 sign if ≥50 ft frontage; a 2nd sign allowed if site has >500 ft frontage (multi-use/multi-tenant) | Properties fronting collectors or other non-arterial ROWs; oriented 45°–90° to ROW; outside sight distance triangle. | — | Unlock | Sec. 34-659(1)(a)-(d); Sec. 34-657(2) |
| Wall Sign (PAMA frontage on principal/minor arterial) | May not extend above roofline; if parapet projects above roof, may not extend above top of parapet | Variable per formula | Shall not extend beyond 75% of the width of the facade (or tenant’s proportional facade) | N/A (mounted to building; projection ≤12 inches) | Generally 1 per ROW-fronting facade; additional allowances as described for parking-facing and multi-tenant/multi-story buildings | On building facades with frontage on a ROW; additional sign may face parking if not abutting single-family developed or zoned property. Wall signs prohibited on facades abutting single-family zoned/developed property. | — | Unlock | Sec. 34-660(a) and (c)(1)-(3); Fig. 2; Sec. 34-660(a)(3)b (no signs on facades abutting single-family) |
| Wall Sign (Collector and all other ROW) | May not extend above roofline; if parapet projects above roof, may not extend above top of parapet | Variable per formula | Shall not extend beyond 75% of the width of the facade (or tenant’s proportional facade) | N/A (mounted to building; projection ≤12 inches) | Up to 2 per building as described | Max two wall signs per building: one per facade with ROW frontage and an optional one facing parking (not abutting single-family). | — | Unlock | Sec. 34-660(d)(1)-(2); Fig. 2 |
| Directional/Informational Sign | Wall-mounted at eye level; suspended signs clearance ≥9 ft (or ≥14 ft over vehicle lanes) | ≤2 sq ft per sign (unless larger approved along collector/other ROW by director via sign plan) | — | ≥5 ft from property lines (freestanding); may be in sight triangle if ≤30 inches high | As needed; along collectors/other ROW number/size/location set by director via sign plan approval | May be freestanding, monument, or wall-mounted; may be in sight triangle if ≤30 inches high; wall-mounted on walls/fences or suspended; oriented to on-site circulation. | — | Unlock | Sec. 34-661(1)-(7) |
| Entrance Feature Sign (Monument) | 6 ft | 24 sq ft (<100 ft frontage) or 64 sq ft (≥100 ft frontage) | — | ≥7 ft from ROW; within 25 ft of entrance | 1 entrance monument OR 2 wall signs (see separate type) | Within 25 ft of development entrance; 7 ft min setback from ROW. | — | Unlock | Sec. 34-663(1)-(7) |
| Entrance Feature Sign (Wall) | 6 ft measured from grade to top of wall sign | Total of two wall entry signs ≤24 sq ft (<100 ft frontage) or ≤64 sq ft (≥100 ft frontage) | — | Within 25 ft of entrance; attached to wall/guardhouse | Up to 2 wall entry signs in lieu of one monument entry sign | Affixed to a perimeter wall or guardhouse within 25 ft of the entrance. | — | Unlock | Sec. 34-663(1)-(7) |
| Billboard (Off-premises sign) | Height of face 14 ft (pole height governed by structural/state regs) | Face size limited by dimensions 14 ft (H) x 48 ft (W) | 48 ft | Per state/federal/FDOT and building code; not specified in detail | Citywide cap of 10 new billboards (post‑7/1/2019) | Only along SR 826 (Palmetto Expressway) and Florida Turnpike; spacing ≥3,500 ft from any existing/new billboard (≥1,500 ft if along Turnpike north of C‑9 Canal). | — | Unlock | Sec. 34-666(1)-(5); Sec. 34-654(5)-(6) |
Single-Family Dwelling Residential District (R-1)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Flags (Single-family/duplex/townhouse/other residential) | Pole ≤5 ft above residence height or ≤35 ft | ≤24 sq ft | — | Front: ≥10 ft; Other: ≥5 ft | 1 flag per property | Front or rear yard only; pole ground-mounted or affixed to wall. | — | Unlock | Sec. 34-665(2) |
| Entrance Feature Sign (for subdivisions/neighborhoods including R-1) | 6 ft | As above | — | Monument: ≥7 ft from ROW; within 25 ft of entrance; Wall: within 25 ft of entrance | 1 monument OR 2 wall entrance signs | Within 25 ft of entrance; wall or monument per standards. | — | Unlock | Sec. 34-663(1)-(7); Sec. 34-651(a) (sign plan exemption for single-family zoned property) |
| Temporary Signs – Residential Categories | Construction ≤10 ft; Noncommercial ≤8 ft; Residential real estate ≤5 ft; ‘Open house’ ≤2 ft | Construction: ≤9 sq ft; Noncommercial speech: ≤9 sq ft (+ ≤9 sq ft during election window); Real estate (primary): ≤4 sq ft; ‘Open house’ extra sign ≤3 sq ft during limited times | — | As specified per temporary sign type | As specified per temporary sign type | On private property; setbacks apply. | — | Unlock | Sec. 34-653(1)(b),(f); Sec. 34-670(a)-(c) |
Multiple-Family Dwelling Residential District (R-15), Multiple-Family Dwelling Residential District (R-25), Multiple-Family Dwelling Residential District (R-50), Neighborhood Commercial District (NC), Planned Corridor Development District (PCD), Light Industrial District (I-1), Heavy Industrial District (I-2), Planned Development District (PD), Agricultural and Utilities District (AU), Office District (OF), Government Properties District (GP), Entertainment Overlay District (EO), Business Transitional Overlay (BTO), Performance Arts, Civic and Entertainment Overlay District (PACE), Innovation Overlay District (INN)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Monument Sign (PAMA frontage on principal/minor arterial) | 10 ft | 65 sq ft per sign (total 130 sq ft if 2 signs) | Width ≤10 ft; proportion 1:1.5 | ≥7 ft from all property lines; clear of sight triangle | 1 if ≥50 ft frontage; up to 2 if criteria met | Frontage on principal/minor arterial; oriented 45°–90° to ROW; outside sight triangle. | — | Unlock | Sec. 34-658(1); Sec. 34-657(2), incl. (m) |
| Monument Sign (Collector and all other ROW) | 6 ft | 54 sq ft per sign (total 108 sq ft if 2 signs allowed) | Width ≤10 ft; proportion 1:1.5 | ≥7 ft from property lines | 1 if ≥50 ft frontage; possible 2nd if >500 ft (multi-tenant/multi-use) | Fronting collectors or other ROWs; oriented 45°–90° to ROW; outside sight triangle. | — | Unlock | Sec. 34-659(1); Sec. 34-657(2) |
| Wall Sign (PAMA) | Below roofline/top of parapet | Variable per formula | ≤75% facade/tenant width | N/A (wall-mounted) | As allowed per Sec. 34-660 for PAMA | ROW-facing facade; 2nd on parking-facing facade if not abutting single-family; multi-tenant & multi-story rules apply. | — | Unlock | Sec. 34-660(a),(c) |
| Wall Sign (Collector/other ROW) | Below roofline/top of parapet | Variable per formula | ≤75% facade/tenant width | N/A | Up to 2 per building | Up to 2 per building: one per ROW-facing facade and one parking-facing (not abutting single-family). | — | Unlock | Sec. 34-660(d) |
| Directional/Informational, Window (Ground & Second Floor), Entrance Feature (Monument & Wall), Directory Signs | Directional ceiling clearance rules; Entrance 6 ft; others per type | Directional ≤2 sq ft; Window Ground ≤40 sq ft (≤20% area); Window Second ≤20 sq ft (≤10% area); Entrance 24/64 sq ft; Directory 3 sq ft | — | As applicable by sign type | As applicable by sign type | Per general standards for each sign type. | — | Unlock | Secs. 34-661, 34-662, 34-663, 34-664 |
| Flags (Nonresidential/multifamily/industrial/commercial/mixed-use) | Pole ≤30 ft or ≤10 ft above roofline (whichever less) | ≤40 sq ft per flag | — | ≥10 ft from all property lines | Max poles: 1 (≤100 ft frontage); 2 (>100–≤200 ft); 3 (>200 ft); max 3 flags/property | Ground poles or building-mounted poles; no rooftop flags. | — | Unlock | Sec. 34-665(1) |
| Automatic Changeable Copy Monument Sign (Option) | Per monument sign | Portion of monument sign (≤30% of sign area) | — | Per monument standards (≥7 ft, etc.) | 1 per development (2 if >50 acres) | Only on parcels ≥10 gross acres; only on monuments; properties must have ≥200 linear ft frontage on arterial or collector; not permitted in R-1 or R-2. | — | Unlock | Sec. 34-657(2)(m)(1)-(9) |
| Drive-Through Lane Signs; Vehicle Fueling/Sales; Theaters/Public Assembly; Temporary Signs (Nonresidential) | Drive-through ≤6 ft; spot/search light no height specified; others per type | Drive-through ≤20 sq ft/sign; Pump signs ≤4 sq ft/pump; Theater manual changeable copy area rules; Temporary banners ≤50 sq ft; Noncommercial speech ≤44 sq ft (+ election window). | — | As applicable by type | As applicable by type | Per general sections for each specialty sign type. | — | Unlock | Secs. 34-667, 34-668, 34-669, 34-670 |
PermitPal covers all 4 zoning districts in Miami Gardens — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 4 zones for Miami Gardens — start freeProhibited Signs in Miami Gardens
- Installing, altering, erecting, constructing, posting, painting, maintaining, or relocating any sign without a city sign permit unless expressly exempt is unlawful.
- No sign may be erected or used in a manner that conflicts with the regulations for the zoning district in which it is located or with the use permitted under the property's certificate of use or occupancy.
- Any sign not in compliance with the sign code is prohibited.
- Signs located so as to constitute a danger to public safety are prohibited.
- Any sign with manual or automatic changeable copy that is not a monument sign is prohibited.
- Window signs above the second floor of any building are prohibited.
- Awning/canopy signs are prohibited.
- Any sign not secured to the ground or affixed to a wall or window in accordance with the Florida Building Code is prohibited.
- Signs located on top of gasoline pumps, unless required by law, are prohibited.
- Signs that imitate or can be confused with traffic control device signs are prohibited.
- Vehicle signs that can be viewed from a public right-of-way are prohibited.
- Roof signs, parapet signs, and signs projecting above a canopy, parapet, or roof of a building are prohibited.
- Any sign that covers, interrupts, or disrupts the major architectural features of a building is prohibited.
- Signs or sign supports that interfere with or obstruct, physically or visually, public alarms, signals, or signs are prohibited.
- Abandoned signs that remain out of compliance for more than 45 days are prohibited.
- Animated signs are prohibited.
- Portable signs are prohibited.
- Snipe signs are prohibited.
- Mascot/figurine/costume signs are prohibited.
- Painted signs and murals are prohibited.
- Any blinking or flashing lights, revolving or rotating signs, streamer lights, pennants, streamers, and other fluttering, spinning, or attention-attracting devices are prohibited.
- Signs displayed within, on, or over public rights-of-way, on public lands, in a required sight visibility triangle, or located so as to impede traffic or pedestrian flow or create an unsafe or hazardous situation on or off the property are prohibited.
- Variances cannot be granted from the prohibited sign list.
Exempt Signs in Miami Gardens
- Government signs on government property (city, county, or State of Florida) and traffic control devices are not regulated by this article.
- The following may be installed or maintained without a city sign permit (though other codes may still apply): government signs or sign structures exempt under the government exemption, construction signs, nameplate signs, utility company signs, flags, and real estate signs for residential uses.
Sign Plan & Submission Notes for Miami Gardens
- A sign plan is required for all permanent signage on property not zoned for single-family residential use; permanent signs must comply with an approved sign plan.
- Approval of a sign plan is required prior to issuance of a building permit to install, alter, erect, construct, post, paint, maintain, or relocate any permanent sign.
- For multi-tenant developments, the property owner must file a sign plan at least 30 days before any individual sign permit application; failure to file is a violation.
- A sign plan must include all permanent signs on the property (including outparcels), showing locations, sizes, copy, sign types/materials/colors, illumination, and associated landscaping.
- Directional/informational wall-mounted signs along collector and other rights-of-way may be allowed as approved by a sign plan permit.
- Window signs must conform to an approved window sign plan; owners of window signs were required to submit a window sign plan by October 1, 2018, and locate all window signs within the same approved 20% window area.
- Nonconforming signs amortization required submission of a sign plan by July 1, 2019, approval by December 31, 2019, and alteration/removal by July 1, 2020, unless specific exceptions apply.
- A variance is required for any sign that does not meet code standards (no variances may be granted for prohibited sign types). Variance approvals are tiered: up to 25% from a standard may be approved by the planning and zoning director; 26%–35% by the city manager; over 35% only after a public hearing before the city council using quasi-judicial procedures.
- Appeals of sign plan or sign permit denials go to the city council for a quasi-judicial hearing; council decisions are final city action subject to court review.
Source: municode municipal code