Great Neck Plaza, New York has specific sign regulations covering 21 sign types across 3 zoning districts. Regulated sign types include Bulletin Board, Real Estate Sign, Construction Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Sign Regulation Overview for Great Neck Plaza, New York
Sample Sign Requirements in Great Neck Plaza
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign - Street Level | Sign top no higher than the lowest of (a) 15 ft above curbline; (b) bottom of sills of first level of windows above the first story; or (c) lowest roofline of the building | No more than 42 sq ft per sign; total exterior sign area for all street-level signs combined as per formula | — |
| Wall Sign - Above Street Level | — | No more than 10 sq ft | — |
| Ground Sign | — | 8 sq ft | Must be set back more than 10 ft from front property line, and sign must be no closer than inside edge of property line |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
21
- Bulletin Board
- Real Estate Sign
- Construction Sign
- Wall Sign - Street Level
- +2 more types
Zoning Districts
3
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Great Neck Plaza
Other Cities in New York
Frequently Asked Questions
In Great Neck Plaza, wall signs can be up to Sign top no higher than the lowest of (a) 15 ft above curbline; (b) bottom of sills of first level of windows above the first story; or (c) lowest roofline of the building. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.
To get a sign permit in Great Neck Plaza, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Great Neck Plaza, regulated sign types include Bulletin Board, Real Estate Sign, Construction Sign, Wall Sign - Street Level, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Great Neck Plaza vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Great Neck Plaza are regulated with specific requirements for brightness, animation, and message duration. Great Neck Plaza has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Great Neck Plaza Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Great Neck Plaza, New York sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Great Neck Plaza, New York Sign Rules at a Glance
Great Neck Plaza, New York regulates 21 sign types across 3 zoning districts. Ground Sign - Shopping Center (Triple-Faced)s in the Nonresidential use zoning district, Nonresidential district, Residential zoning district (appurtenant to a nonresidential use) zoning district are capped at 5 ft vertical face; max 15 ft high from ground tall and 25 sq ft (per face), with a Building must have >50% frontage set back more than 10 ft setback (Sec. § 225-110B(1)). Most commercial signs in Great Neck Plaza require a permit.
Detailed Sign Ordinance Requirements for Great Neck Plaza, New York
Sign Rules by Zoning District in Great Neck Plaza (3 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Nonresidential use zoning district, Nonresidential district, Residential zoning district (appurtenant to a nonresidential use) | 15 | Sign top no higher than the lowest of (a) 15 ft above curbline; (b) bottom of sills of first level of windows above the first story; or (c) lowest roofline of the building | 50% greater than otherwise permitted | — |
| Residential zoning district, Residential district | 2 | Conform to nonresidential sign top requirements | 10 sq ft (total) | — |
| General Regulations For All Zones | 7 | — | 36 sq in (6x6 in) per sign/decal (or placard) | — |
Zone-by-Zone Sign Requirements in Great Neck Plaza
Nonresidential use zoning district, Nonresidential district, Residential zoning district (appurtenant to a nonresidential use)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign - Street Level | Sign top no higher than the lowest of (a) 15 ft above curbline; (b) bottom of sills of first level of windows above the first story; or (c) lowest roofline of the building | No more than 42 sq ft per sign; total exterior sign area for all street-level signs combined as per formula | 20 ft | — | One exterior mounted sign, one interior mounted sign per design unit. Corner lots may be granted 1 additional exterior by special permit. | Mounted on the face or within a door/window of the building, parallel to the building face (unless on awning), may project max 12 in from surface (except as authorized) | — | Unlock | § 225-105, § 225-106, § 225-107A(1-15), § 225-110 |
| Wall Sign - Above Street Level | — | No more than 10 sq ft | — | — | One per qualifying business above street level | On (or behind/painted on) window facing street, or pinned-on letters to building face (over 20 ft frontage only) | — | Unlock | § 225-110K |
| Ground Sign | — | 8 sq ft | — | Must be set back more than 10 ft from front property line, and sign must be no closer than inside edge of property line | One per building | For building set back more than 10 feet; sign no closer to street than inside edge of property line | — | Unlock | § 225-110A |
| Ground Sign - Shopping Center (Triple-Faced) | 5 ft vertical face; max 15 ft high from ground | 25 sq ft (per face) | — | Building must have >50% frontage set back more than 10 ft | One per qualifying shopping center | No closer to the street than inside edge of property line; must not obstruct driver view | — | Unlock | § 225-110B(1) |
| Projecting Sign | — | — | 3 ft horizontal, 3 ft vertical; projects no more than 4 ft from face | — | Not specified | Wall-mounted, double-faced, or 3D symbol/model | — | Unlock | § 225-110D |
| Sale Sign | — | 3 sq ft | — | — | One per display window | In display windows of a design unit | — | Unlock | § 225-109B |
| Bulletin Board | — | 6 sq ft | — | — | One per full 20 ft of frontage | Located behind show window (first story only) | — | Unlock | § 225-109G |
| Parking Facility Sign | — | 9 sq ft | — | — | One per vehicular entrance | At each vehicular entranceway to parking facility | — | Unlock | § 225-110L |
Residential zoning district, Residential district
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Residential Name/Professional Sign | Conform to nonresidential sign top requirements | 1 sq ft | — | — | — | On premises | — | Unlock | § 225-107B |
| Multiresidential Building Identification Sign - Ground or Wall | — | 10 sq ft (total) | — | — | One per apartment/condo/co-op building | — | — | Unlock | § 225-110C |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Real Estate Sign | — | 2 sq ft | — | — | — | On premises for sale/lease/rent | — | Unlock | § 225-109A |
| Construction Sign | — | 15 sq ft | — | — | — | Erected during construction/alteration (temporary) | — | Unlock | § 225-109C |
| Bulletin Board | — | 6 sq ft | — | — | One per full 20 ft of frontage | Behind first story show window | — | Unlock | § 225-109G |
| Charge Card/Price Placard | — | 36 sq in (6x6 in) per sign/decal (or placard) | — | — | Max 5 charge card signs/unit, unlimited price placards | Affixed on or behind window/door (first-story retail) | — | Unlock | § 225-109E, § 225-109F |
| Exit Sign (Fire Code) | — | — | — | — | — | Over all exit doors or equivalent opening forming part of an exit | — | Unlock | § 114-15 |
| Age-Restricted Product Notice | — | — | — | — | — | Posted in a conspicuous place at point of sale | — | Unlock | § 169-3 |
| Secondhand Merchandise Label | — | — | — | — | All qualifying merchandise | On all secondhand merchandise sold by dealers selling both new/secondhand | — | Unlock | § 171-21 |
Illumination rules, size formulas, and permit requirements for every sign type in Great Neck Plaza are available with a free PermitPal account.
Start freeProhibited Signs in Great Neck Plaza
- No sign, attracting device, or design unit subject to a design development plan may be erected, altered, or reconstructed (except for normal maintenance) without a permit from the Village Board of Trustees, except as provided otherwise.
- The Village Board of Trustees may deny a permit for any sign or attracting device which, in its reasonable judgment, is misleading and dangerous due to physical composition or contents creating a substantial risk of misidentification impeding emergency services.
- No sign for a design unit shall contain or consist of moving parts or intermittent light, excluding traditional barber poles.
- No system and/or equipment which conveys, projects, or illuminates a symbol or image is permitted.
- Internally illuminated neon signs and exposed neon signs are not permitted unless a special permit is authorized by the Board of Trustees.
- Signs shall use no more than three colors (including black and white), none of which may be fluorescent or Day-Glo colors.
- Signs may display only the name and address of the occupant, and in no more than three words, identify the nature of the service or business. One logo or symbol is permitted (occupying no more than 10% of the allowable sign area).
- Signs for a design unit must be attached on their entire surface to the face of a building or within a door or window, unless otherwise authorized.
- Signs may not exceed 20 feet in length or 42 square feet in area.
- Signs for a design unit may not project outward more than 12 inches from the surface to which attached, unless on a canopy or awning or otherwise authorized.
- Signs for a design unit, unless on an awning, must be parallel to the plane of the building face.
- Residential signs appurtenant to a residential use in any residential district are limited to displaying name, address, or profession, must be no larger than one square foot, and not be illuminated (unless professional, with Board approval).
- Signs now or hereafter existing which no longer advertise a bona fide business, product, or service must be removed by the owner within 30 days of cessation.
- Attracting devices may not contain or consist of moving parts or intermittent light.
- Signs not maintained in a clean, sightly, and safe condition must be restored or replaced; defects must be remedied within 10 business days of directive.
Exempt Signs in Great Neck Plaza
- No permit is required for real estate signs in any use district advertising the sale, lease, or rental of the premises upon which the sign is located, up to two square feet and otherwise conforming to requirements.
- No permit is required for sale signs in any nonresidential district or appurtenant to a nonresidential use in a residential district advertising special sales or events, not exceeding 14 days, with a maximum of three square feet per sign, limited one per display window, and legend limited to 'Sale,' 'Spring Sale,' etc.
- No permit is required for construction signs temporarily erected during construction or alteration of the design unit, up to 15 square feet, removed when work is complete, and otherwise conforming to requirements.
- No permit is required for political signs incident to an election, displayed no more than 60 days prior to and five days after the election, not attached to tree, post, utility pole or fence, not obstructing vision, conforming to requirements (except area may be 50% greater).
- No permit is required for charge card signs, decals or placards affixed on or behind window/door of first-story retail store, not exceeding six inches by six inches, limited to five per design unit.
- No permit is required for price placards not exceeding six inches by six inches advertising only the price of the attached goods.
- No permit is required for bulletin boards (one per 20 feet of frontage) behind first-story show window, for sale items, specials, or menus, up to six square feet, framed, no Day-Glo colors, not internally illuminated.
- No permit is required for signs for professional offices above street level, if landlord permits, on/adjacent to entry door, projecting no more than three inches, nonilluminated, and not exceeding one square foot.
Sign Plan & Submission Notes for Great Neck Plaza
- No sign, attracting device, or design unit subject to a design development plan may be erected, altered or reconstructed (except for normal maintenance) without a permit from the Village Board of Trustees, after compliance with requirements and after receipt of a design report in accordance with §225-106.
- Before a permit for a sign or attracting device is granted, the permit application shall be referred to the Building Inspector for a report, who examines conformity and reports to the Board of Trustees at a regular monthly meeting.
- Permit applications must include such other information (photographs, drawings) as reasonably necessary to establish compliance, including any required design review.
- The Board of Trustees issues special permits (e.g., for attracting devices, neon signs, projecting signs, signs above street level) only after receipt of a design report and recommendation by the Building Inspector.
- A complete plan of parking field entrance and directional signs shall be submitted to the Board of Trustees for its approval.