Honeoye Falls, New York has specific sign regulations covering 17 sign types across 7 zoning districts. Regulated sign types include Ground Sign, Wall Sign, Temporary Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Honeoye Falls, New York
Sample Sign Requirements in Honeoye Falls
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Directional Sign | 3 ft | 6 sq ft (residential); 16 sq ft (nonresidential) | Not listed |
| Gasoline Pump Sign | Not listed | 6 sq ft | Not listed |
| Governmental Sign | Not listed | No size requirement | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
17
- Ground Sign
- Wall Sign
- Temporary Sign
- Neon Sign
- +2 more types
Zoning Districts
7
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Honeoye Falls
Other Cities in New York
Frequently Asked Questions
In Honeoye Falls, the height limit for Pole Sign in the General Business District (GB) is 10 ft (Sec. 190-130C(1)-(4)). The height limit for Wall Sign in the General Business District (GB) is 6 ft (Sec. 190-130E(1)-(3)). Maximum sign heights range from 3 ft to 24 in across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Honeoye Falls require a permit. From the submission notes on this page: Application for a temporary hanging sign (event sign) must be submitted and approved by the Village Zoning Board of Appeals following the specified criteria. Run a code check for an exact address to see the permit requirements for that zone.
Honeoye Falls's sign code covers 17 sign types, including Ground Sign, Wall Sign, Temporary Sign, and Neon Sign. Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Signs attached to a gasoline pump are exempt from a permit if they do not exceed six square feet in area and are not illuminated. The full list is on this page.
This page doesn't list a single setback distance for signs in Honeoye Falls. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Honeoye Falls's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.
Ready to Research Honeoye Falls Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Honeoye Falls, New York, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Honeoye Falls, New York Sign Rules at a Glance
Honeoye Falls, New York regulates 17 sign types across 7 zoning districts. Wall Signs in the Central Business District (CB) are capped at 4 ft tall and 16 sq ft (Sec. 190-130E(1)-(3)). Most commercial signs in Honeoye Falls require a permit.
Detailed Sign Ordinance Requirements for Honeoye Falls, New York
Sign Rules by Zoning District in Honeoye Falls (7 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 7 | 3 ft | 6 sq ft (residential); 16 sq ft (nonresidential) | Not listed |
| Residential District (R-1, R-2, R-3, R-4) | 3 | 3 ft | 12 sq ft | Not listed |
| Neighborhood Business District (NB) | 7 | 15 in | 25% of window area | Not listed |
| Central Business District (CB) | 8 | 15 in | 30% of window area | Not listed |
| General Business District (GB) | 9 | 24 in | 36 sq ft | Not listed |
| Light Industrial, Manufacturing Industrial Districts (LI, MI) | 7 | 8 ft | 36 sq ft | Not listed |
| Nonresidential Districts | 1 | Not listed | 10% of window area | Not listed |
Zone-by-Zone Sign Requirements in Honeoye Falls(sample of 3 of 7 zones)
Neighborhood Business District (NB)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | 15 in | Not listed | Not listed | Not listed | 1 per awning | Flat against awning, not beyond valence or on underside; must have 8 ft minimum clearance | Not listed | Unlock | § 190-130A(1)-(2) |
| Ground Sign | 4 ft | 12 sq ft | Not listed | Principal structure must be set back at least 20 ft from front property line. | 1 per lot | Principal structure must be set back at least 20 ft from front property line; landscaped area extending 1 ft beyond sign base required. | Not listed | Unlock | § 190-130B(1)-(4) |
| Projecting or Suspended Sign | 3 ft | 10 sq ft | Not listed | Not listed | 1 per use | Must be supported by building; can overhang public right-of-way with insurance naming Village as insured party. | Not listed | Unlock | § 190-130D(1)-(5) |
| Wall Sign | 4 ft | 12 sq ft | Not listed | Not listed | 2 per use | Not listed | Not listed | Unlock | § 190-130E(1)-(3) |
| Window Sign | Not listed | 25% of window area | Not listed | Not listed | Not listed | On or within 3 ft of window. | Not listed | Unlock | § 190-130F(1)-(2) |
| Temporary Sign | 4 ft | 24 sq ft | Not listed | Not listed | 1 per use | Not listed | Not listed | Unlock | § 190-130G(1)-(3) |
| Neon Sign | Not listed | 10% of window area | Not listed | Not listed | 2 per use | Window | Not listed | Unlock | § 190-128(F) |
Central Business District (CB)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | 15 in | Not listed | Not listed | Not listed | 1 per awning | Flat against awning, not beyond valence or on underside; must have 8 ft minimum clearance | Not listed | Unlock | § 190-130A(1)-(2) |
| Ground Sign | 4 ft | 16 sq ft | Not listed | Principal structure must be set back at least 20 ft from front property line. | 1 per lot | Principal structure must be set back at least 20 ft from front property line; landscaped area extending 1 ft beyond sign base required. | Not listed | Unlock | § 190-130B(1)-(4) |
| Projecting or Suspended Sign | 3 ft | 10 sq ft | Not listed | Not listed | 1 per use | Must be supported by building; can overhang public right-of-way with insurance naming Village as insured party. | Not listed | Unlock | § 190-130D(1)-(5) |
| Wall Sign | 4 ft | 16 sq ft | Not listed | Not listed | 2 per use | Not listed | Not listed | Unlock | § 190-130E(1)-(3) |
| Window Sign | Not listed | 30% of window area | Not listed | Not listed | Not listed | On or within 3 ft of window. | Not listed | Unlock | § 190-130F(1)-(2) |
| Temporary Sign | 4 ft | 24 sq ft | Not listed | Not listed | 1 per use | Not listed | Not listed | Unlock | § 190-130G(1)-(3) |
| Neon Sign | Not listed | 10% of window area | Not listed | Not listed | 2 per use | Window | Not listed | Unlock | § 190-128(F) |
| Sandwich Board Sign (CB - Right-of-Way Option) | 3 ft | Not listed | 2 ft | Not listed | 1 per use | May be in public right-of-way; must not impede visibility/access; must be brought in at close of business. | Not listed | Unlock | § 190-128(H)(4) |
General Business District (GB)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | 24 in | Not listed | Not listed | Not listed | 1 per awning | Flat against awning, not beyond valence or on underside; must have 8 ft minimum clearance | Not listed | Unlock | § 190-130A(1)-(2) |
| Ground Sign | 8 ft | 32 sq ft | Not listed | Principal structure must be set back at least 20 ft from front property line. | 1 per lot | Principal structure must be set back at least 20 ft from front property line; landscaped area extending 1 ft beyond sign base required. | Not listed | Unlock | § 190-130B(1)-(4) |
| Pole Sign | 10 ft | 12 sq ft | Not listed | Principal structure must be set back at least 20 ft from front property line. | 1 per lot | Principal structure must be set back at least 20 ft from front property line; landscaped area of at least 4 sq ft at base required. | Not listed | Unlock | § 190-130C(1)-(4) |
| Projecting or Suspended Sign | 4 ft | 16 sq ft | Not listed | Not listed | 1 per use | Must be supported by building; can overhang public right-of-way with insurance naming Village as insured party. | Not listed | Unlock | § 190-130D(1)-(5) |
| Wall Sign | 6 ft | 1 sq ft per linear foot of building frontage or 20% of facade, whichever is less | Not listed | Not listed | 3 per use | Not listed | Not listed | Unlock | § 190-130E(1)-(3) |
| Window Sign | Not listed | 30% of window area | Not listed | Not listed | Not listed | On or within 3 ft of window. | Not listed | Unlock | § 190-130F(1)-(2) |
| Temporary Sign | 6 ft | 36 sq ft | Not listed | Not listed | 1 per use | Not listed | Not listed | Unlock | § 190-130G(1)-(3) |
| Neon Sign | Not listed | 10% of window area | Not listed | Not listed | 2 per use | Window | Not listed | Unlock | § 190-128(F) |
PermitPal covers all 7 zoning districts in Honeoye Falls. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Honeoye Falls
- Any sign for which no sign permit was issued, for which a sign permit was revoked, or any other sign not explicitly authorized herein.
- Any sign that is not properly maintained, considered structurally unsound, hazardous, or otherwise unsafe.
- Any sign placed on a curb, sidewalk, hydrant, utility pole, tree or other object located on or over any public street unless otherwise permitted by this article.
- Any sign that advertises an activity, business, product or service no longer conducted or available on the premises on which the sign is located.
- Any sign that is located off-premises from the use and/or structure to which it serves, unless otherwise permitted by this article.
- Any sign that contains words or pictures of an obscene or pornographic nature.
- Any sign that emits audible sounds, odor, or visible matter.
- Any sign that may be confused with a traffic control sign, signal or device or the light of an emergency or road equipment vehicle or any sign which hides from public view any traffic or street sign, signal, or device.
- Any sign that flashes, blinks, rotates, or revolves, or utilizes unshielded lighting devices, mirrors, or reflective material.
- Any internally illuminated sign, except signs utilizing reverse channel lettering.
- Any sign that is mounted on wheels or mounted on any structure on wheels.
- Any sign that is painted directly on a wall, fence, or other structure.
- Any sign erected upon or projecting above the roof of a structure.
- Any banner, poster, pennant, ribbon, streamer, spinner, or balloon, unless such material is utilized as temporary signage subject to the regulations of § 190-130G.
Exempt Signs in Honeoye Falls
- Directional signs that provide direction to pedestrians, bicyclists, or motorists are exempt from a sign permit if they are entirely on the relevant property, have no commercial message, do not exceed size/height restrictions, do not extend above the first floor, do not project beyond property lines, and are not illuminated (illumination requires a permit).
- Signs attached to a gasoline pump are exempt from a permit if they do not exceed six square feet in area and are not illuminated.
- Any official governmental sign, public notice, or warning sign supported by federal, state or local law is exempt from permits, size and time limits.
- Signs within a building or structure not legible from the public right-of-way or adjacent lots, or signs within an enclosed outdoor space, such as an athletic field, intended only to be seen from within, are exempt.
- Lawn signs are exempt from a permit if no single sign exceeds three feet in height and six square feet in area, is not displayed for more than 60 days in a ninety-day period, is not illuminated, and the cumulative area of all signs on the lot does not exceed 12 square feet.
- Neon signs in nonresidential districts are exempt if there is no more than one neon sign per window (not exceeding 10% of window area) and no more than two per use.
- Noncommercial signs (without a commercial message) are exempt if limited to one per use, not exceeding three feet in height and six square feet in area, and not illuminated.
- Sandwich board signs are exempt from a permit if limited to one per use, not illuminated, not exceeding three feet in height and two feet in width, not located in the public right-of-way unless in Central Business District and not impeding access or visibility, and brought in each day at close of business.
Sign Plan & Submission Notes for Honeoye Falls
- Application for a temporary hanging sign (event sign) must be submitted and approved by the Village Zoning Board of Appeals following the specified criteria.
- Temporary signs require the issuance of a permit from the CEO.
- Directional signs require a permit if illuminated.
- Ordinance references approval/permit requirements per sign type and use, but no explicit requirement for a master sign plan or sign plan for all projects/uses identified in the provided text.
Source: ecode360 municipal code