Sign Regulations in Sand Springs, Oklahoma

Sand Springs, Oklahoma has specific sign regulations covering 18 sign types across 8 zoning districts. Regulated sign types include Wall Sign, Projecting Sign, Freestanding Ground Sign (Business). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: January 14, 2026

Sign Regulation Overview for Sand Springs, Oklahoma

Sample Sign Requirements in Sand Springs

Sign TypeMax HeightMax AreaSetback
Wall SignMay extend above parapet/building wall only as needed to allow a wall sign of 3 feet in height; otherwise shall not extend above top of parapet or building wall50 ft (visible from R District/designated residential area); 200 ft (if >300 sq ft and visible from R District/designated residential area); centerline setback = one-half ROW width or 25 ft if undesignated
Projecting Sign18 inches from curb; residential visibility setbacks and centerline setbacks apply
Freestanding Ground Sign (Business)10 ft minimum from designated state or federal highway ROW; residential visibility setbacks (50 ft/200 ft when >300 sq ft); centerline setback one-half ROW width or 25 ft if undesignated

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Sand SpringsFull Coverage

Sign Types Covered

18

  • Wall Sign
  • Projecting Sign
  • Freestanding Ground Sign (Business)
  • Portable Business Sign
  • +2 more types

Zoning Districts

8

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Sand Springs

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Sand Springs, wall signs can be up to May extend above parapet/building wall only as needed to allow a wall sign of 3 feet in height; otherwise shall not extend above top of parapet or building wall. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Sand Springs, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Sand Springs, regulated sign types include Wall Sign, Projecting Sign, Freestanding Ground Sign (Business), Portable Business Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Sand Springs, monument signs typically require a 10 ft minimum from designated state or federal highway ROW; residential visibility setbacks (50 ft/200 ft when >300 sq ft); centerline setback one-half ROW width or 25 ft if undesignated setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Sand Springs are regulated with specific requirements for brightness, animation, and message duration. Sand Springs has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Sand Springs Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Sand Springs, Oklahoma sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Sand Springs, Oklahoma Sign Rules at a Glance

Sand Springs, Oklahoma regulates 18 sign types across 8 zoning districts. Portable Business Signs in the General Regulations For All Zones zoning district are capped at 12 ft tall and 32 sq ft display surface area, with a General setbacks apply (residential visibility, centerline setbacks, highway ROW setbacks). For inflatable promotional signs see Promotional Business Sign setback (Sec. Section 13.21.C.19(a)-(c)). Most commercial signs in Sand Springs require a permit.

Detailed Sign Ordinance Requirements for Sand Springs, Oklahoma

Sign Rules by Zoning District in Sand Springs (8 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones1820 ftIf on a window, display area may not cover more than 50% of the window
Commercial Shopping Center District (CS)512 ft32 sq ft
Industrial Light District (IL)512 ft32 sq ft
Commercial High Intensity District (CH)512 ft32 sq ft
Commercial General District (CG)512 ft32 sq ft
Central Business District (CBD)512 ft32 sq ft
Industrial Moderate District (IM)512 ft32 sq ft
Industrial Heavy District (IH)512 ft32 sq ft

Zone-by-Zone Sign Requirements in Sand Springs(sample of 3 of 8 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignMay extend above parapet/building wall only as needed to allow a wall sign of 3 feet in height; otherwise shall not extend above top of parapet or building wall50 ft (visible from R District/designated residential area); 200 ft (if >300 sq ft and visible from R District/designated residential area); centerline setback = one-half ROW width or 25 ft if undesignatedNot subject to the per-lot maximum in 13.21.C.9On building wall/parapetUnlockSection 13.21.C.12; 13.21.C.1(a)-(b); 13.21.C.6; 13.21.C.7; 13.21.C.13; 13.21.C.15
Portable Business Sign12 ft32 sq ft display surface areaGeneral setbacks apply (residential visibility, centerline setbacks, highway ROW setbacks). For inflatable promotional signs see Promotional Business SignSubject to zone-specific shared cap for business signs (excluding wall/promotional) per 13.21.C.9; permit time limits as statedOn ground, anchored in masonry base or an approved system with decorative skirting obscuring all portions below bottom of faceUnlockSection 13.21.C.19(a)-(c)
Promotional Business SignMaximum height shall not exceed the height of any ground sign permitted on the lotInflatable promotional signs: setback from property lines one foot per foot of height; general setbacks applyUp to 4 permits/year per business; each for 10 days; may run consecutivelyNot permitted on the roof except inflatable or other non-rigid promotional business signs; inflatable promotional signs must be set back from property lines one foot for every foot of height (measured from base)UnlockSection 13.21.C.8(a)-(b); 13.21.C.2; 13.21.C.11
Roof Sign (Promotional Only)Subject to Promotional Business Sign height limit (not to exceed height of any ground sign permitted on the lot)General setbacks applyWithin promotional permit limitsOn roof (inflatable/non-rigid promotional signs only)UnlockSection 13.21.C.8(b)(2); 13.21.C.11
Banner (Wall-Attached)32 sq ftGeneral setbacks applyNot specifiedAttached to the wall of a buildingUnlockSection 13.21.C.4(m); 13.21.C.2; 13.21.C.7
Temporary Construction Sign20 ftBetween 32 sq ft and 300 sq ftGeneral setbacks applyNot specifiedOn each arterial street frontage of the developmentUnlockSection 13.21.C.4(c); 13.21.C.2; 13.21.C.7
Nameplate (Wall)4 sq ftGeneral setbacks applyNot specifiedOn building wallUnlockSection 13.21.C.4(a); 13.21.C.2; 13.21.C.7
Window SignIf on a window, display area may not cover more than 50% of the windowGeneral setbacks applyNot specifiedWithin building or on window as specifiedUnlockSection 13.21.C.4(i); 13.21.C.2; 13.21.C.7

Commercial Shopping Center District (CS)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Ground Sign (Business)10 ft from state/federal highway ROW; residential visibility setbacks (50 ft/200 ft if >300 sq ft); centerline setback one-half ROW width or 25 ftOne per each 150 ft of arterial street frontage or fraction thereof (shared cap across business sign types other than wall/promotional)On ground; not within public right-of-way without approvalsUnlockSection 13.21.C.9(a); 13.21.C.10; 13.21.C.16; 13.21.C.17; 13.21.C.1(a)-(c); 13.21.C.6; 13.21.C.18; 13.21.C.15
Projecting Sign18 inches from curb; residential visibility setbacks; centerline setbackSubject to shared cap: one per 150 ft arterial frontage or fraction thereofSet back minimum 18 inches from curbUnlockSection 13.21.C.9(a); 13.21.C.1(d); 13.21.C.17; 13.21.C.1(a)-(b); 13.21.C.6
Wall SignMay extend above parapet/building wall only as needed to allow a 3-ft-high signGeneral setbacks applyNot subject to per-lot maximum in 13.21.C.9On building wall/parapetUnlockSection 13.21.C.12; 13.21.C.2; 13.21.C.9
Portable Business Sign12 ft32 sq ftGeneral setbacks applySubject to shared cap for business signs (excluding wall/promotional)On groundUnlockSection 13.21.C.19(a)-(c); 13.21.C.9(a)
Promotional Business SignNot to exceed height of any ground sign permitted on the lotInflatable setback per height; general setbacks applyMax 4 permits/year; each 10 daysOn site; roof allowed only for inflatable/non-rigid promotional signsUnlockSection 13.21.C.8(a)-(b); 13.21.C.11

Industrial Light District (IL)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Ground Sign (Business)10 ft from state/federal highway ROW; residential visibility setbacks (50 ft/200 ft if >300 sq ft); centerline setback one-half ROW width or 25 ftOne per each 150 ft OR one per each 100 ft of arterial street frontage or fraction thereof (shared cap across business sign types other than wall/promotional). Ambiguity in ordinance.On ground; not within public right-of-way without approvalsUnlockSection 13.21.C.9(a) and 13.21.C.9(b); 13.21.C.10; 13.21.C.16; 13.21.C.17; 13.21.C.1(a)-(c); 13.21.C.6; 13.21.C.18; 13.21.C.15
Projecting Sign18 inches from curb; residential visibility setbacks; centerline setbackSubject to shared cap per 13.21.C.9; ordinance lists IL in both 150 ft and 100 ft categoriesSet back minimum 18 inches from curbUnlockSection 13.21.C.9(a) and (b); 13.21.C.1(d); 13.21.C.17; 13.21.C.1(a)-(b); 13.21.C.6
Wall SignMay extend above parapet/building wall only as needed to allow a 3-ft-high signGeneral setbacks applyNot subject to per-lot maximum in 13.21.C.9On building wall/parapetUnlockSection 13.21.C.12; 13.21.C.2; 13.21.C.9
Portable Business Sign12 ft32 sq ftGeneral setbacks applySubject to shared cap (see IL cap ambiguity)On groundUnlockSection 13.21.C.19(a)-(c); 13.21.C.9
Promotional Business SignNot to exceed height of any ground sign permitted on the lotInflatable setback per height; general setbacks applyMax 4 permits/year; each 10 daysOn site; roof allowed only for inflatable/non-rigid promotional signsUnlockSection 13.21.C.8(a)-(b); 13.21.C.11

PermitPal covers all 8 zoning districts in Sand Springs — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 8 zones for Sand Springs — start free

Prohibited Signs in Sand Springs

  • Outdoor advertising signs are prohibited (Ordinance No. 1086; see Section 15.04(A)).
  • No flashing sign is permitted in any district.
  • No sign may be erected, continued, or placed without first securing a permit.
  • Any sign that does not have a current permit must be removed and disposed of according to law.
  • If visible from an R District (other than street, highway or freeway right-of-way) or from a designated residential development area, signs must not be located within 50 feet of that district or area.
  • If larger than 300 square feet and visible from an R District (other than street, highway or freeway right-of-way) or from a designated residential development area, signs must not be located within 200 feet of that district or area.
  • No sign may be located within 10 feet of a designated state or federal highway right-of-way.
  • Projecting signs must be set back at least 18 inches from the curb.
  • No sign may be placed closer to the centerline of an abutting street than one-half the designated right-of-way width (or 25 feet if the street is not designated on the Major Street and Highway Plan), in addition to any other required setback.
  • No sign is permitted in the right-of-way of a public street unless the sign owner has a license and removal agreement with the City and approval from the Board of Adjustment.
  • No ground sign may be located nearer than 35 feet from the intersection of two street rights-of-way or from the intersection of a street right-of-way and a railroad track right-of-way.
  • No ground sign or projecting sign may be located so as to obstruct, obscure, or interfere with any traffic signal light or warning signal light or other emergency/public safety purpose.
  • A sign may not be located within a required parking space or loading berth, may not obstruct vehicular or pedestrian access or circulation, and may not pose any hazard to motor vehicle traffic exiting, entering, or traveling within the site.
  • Roof signs are prohibited except as otherwise permitted in Section 13.21.C.8; existing lawful roof signs are regulated by Chapter 15.

Exempt Signs in Sand Springs

  • One nameplate attached to a wall face not exceeding 4 square feet.
  • Temporary real estate signs.
  • Temporary construction signs on each arterial street frontage of a development, not less than 32 square feet, not more than 300 square feet, and not exceeding 20 feet in height.
  • Signs not visible from a public street.
  • Tablets built into a building or structure used for inscriptions, memorial tablets, or similar purposes.
  • Signs of warning, directive, or instructional nature erected by a public utility, franchised transportation company, or governmental agency.
  • Legal notices and street numbers.
  • Election campaign signs erected not more than 10 days prior to an election and removed within 5 days following the election.
  • Signs within a building located more than 15 inches from any window; signs within a building located less than 15 inches from any window that are oriented to be primarily visible from inside the building; signs on a window when the display surface area does not cover more than 50 percent of the window.
  • Warning, directive, or instructional signs not exceeding 3 square feet of display surface area, including entrance, exit, and restroom signs.
  • Signs attached as labels of a commodity offered for sale.
  • Manufacturer/make/model identification on accessory equipment or structures (e.g., satellite dishes, air conditioners, fences), limited to 25 square inches per piece of equipment or structure.
  • A banner attached to a building wall not exceeding 32 square feet, maintained in good appearance and condition.

Sign Plan & Submission Notes for Sand Springs

  • No master sign plan or sign plan requirement is referenced in the provided text.
  • A sign permit is required before erecting any sign; signs without a current permit must be removed; fees are set by City Council resolution.
  • Signs located within the public street right-of-way require a license and removal agreement with the City and approval by the Board of Adjustment.
  • Portable sign permit extension periods are subject to approval by the Board of Adjustment.

Source: other municipal code