Sign Regulations in Carrollton, Texas

Carrollton, Texas has specific sign regulations covering 37 sign types across 8 zoning districts. Regulated sign types include Monument Sign, Pylon Sign, Pole Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 7, 2025

Sign Regulation Overview for Carrollton, Texas

Sample Sign Requirements in Carrollton

Sign TypeMax HeightMax AreaSetback
Monument Sign6 ft (including base); 12 ft for lots >3 acres or anchor tenants >20,000 sq ft60 sq ft (lots ≤3 acres); 100 sq ft (lots >3 acres)25 ft from back of curb or edge of pavement; comply with Visibility Ordinance
Pylon Sign20 ft (lots >5 acres or anchor tenants >50,000 sq ft)160 sq ft (lots >5 acres)25 ft from back of curb or edge of pavement; comply with Visibility Ordinance
Pole Sign35 ft (≤3 acres abutting IH-35E); 50 ft (>3 acres abutting IH-35E)125 sq ft (≤3 acres abutting IH-35E); 250 sq ft (first sign, >3 acres abutting IH-35E); 125 sq ft for additional sign on same lot25 ft from back of curb/edge of pavement; comply with Visibility Ordinance

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for CarrolltonFull Coverage

Sign Types Covered

37

  • Monument Sign
  • Pylon Sign
  • Pole Sign
  • Wall Sign
  • +2 more types

Zoning Districts

8

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Carrollton

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Carrollton, monument signs are limited to 6 ft (including base); 12 ft for lots >3 acres or anchor tenants >20,000 sq ft. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Carrollton, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Carrollton, regulated sign types include Monument Sign, Pylon Sign, Pole Sign, Wall Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Carrollton, monument signs typically require a 25 ft from back of curb or edge of pavement; comply with Visibility Ordinance setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Carrollton are regulated with specific requirements for brightness, animation, and message duration. Carrollton has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Carrollton Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Carrollton, Texas sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Carrollton, Texas Sign Rules at a Glance

Carrollton, Texas regulates 37 sign types across 8 zoning districts. Monument Signs in the General Regulations For All Zones zoning district are capped at 6 ft (including base); 12 ft for lots >3 acres or anchor tenants >20,000 sq ft tall and 60 sq ft (lots ≤3 acres); 100 sq ft (lots >3 acres), with a 25 ft from back of curb or edge of pavement; comply with Visibility Ordinance setback (Sec. Sec. 151.30). Most commercial signs in Carrollton require a permit.

Detailed Sign Ordinance Requirements for Carrollton, Texas

Sign Rules by Zoning District in Carrollton (8 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones1735 ft (≤3 acres abutting IH-35E); 50 ft (>3 acres abutting IH-35E)225 sq ft per sign
Transit Center District1348 in225 sq ft
Old Downtown Commercial District1
Area 1 (PD-169: Carroll Avenue addresses) (Single-Family Residential Districts), Area 3 (PD-169: 1017 Clint Street) (Single-Family Residential Districts), Single-Family Residential Districts, Single-Family Residential District (SF-12/20)28 ft36 sq ft
Area 2 (PD-169: Belt Line Road addresses west of Larner Street and 1011 Clint Street) (Local Retail District (LR-2)), Local Retail District (LR-2)24 ft50 sq ft per 100 ft of wall (facing Belt Line or Clint); 6 sq ft if rear wall (off-street parking)
Area 4 (PD-169: Belt Line Road addresses east of Larner Street and west of Josey Lane) (Single-Family Residential District (SF-12/20))24 ft15 sq ft
LI Districts112 ft32 sq ft (LI and lots >2 acres); Exception: 96 sq ft for multi-use development/res subdivisions
1 more zone in PermitPal — start free

Zone-by-Zone Sign Requirements in Carrollton(sample of 3 of 8 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Monument Sign6 ft (including base); 12 ft for lots >3 acres or anchor tenants >20,000 sq ft60 sq ft (lots ≤3 acres); 100 sq ft (lots >3 acres)25 ft from back of curb or edge of pavement; comply with Visibility Ordinance1 per lot; more per frontage for large/anchor tenants and special cases as outlinedOn premises of advertised useUnlockSec. 151.30
Pylon Sign20 ft (lots >5 acres or anchor tenants >50,000 sq ft)160 sq ft (lots >5 acres)25 ft from back of curb or edge of pavement; comply with Visibility Ordinance1 per lot; see exceptions for lots >3 acres, per frontage, >20 acres, etc.On premises of advertised useUnlockSec. 151.31
Pole Sign35 ft (≤3 acres abutting IH-35E); 50 ft (>3 acres abutting IH-35E)125 sq ft (≤3 acres abutting IH-35E); 250 sq ft (first sign, >3 acres abutting IH-35E); 125 sq ft for additional sign on same lot25 ft from back of curb/edge of pavement; comply with Visibility Ordinance1 per lot, more for additional freestanding buildings, >3 acres, per frontage, >20 acres, etc.Adjacent to IH-35E onlyUnlockSec. 151.32
Ground SignLots <2 acres: 8 ft; lots >2 acres: 12 ftLots <2 acres: 16 sq ft; lots >2 acres or LI Districts: 32 sq ft; exception: 96 sq ft multiple-use dev/res subdivisions25 ft from curb/edge, 50 ft separation from other signs1 per legal lot; >3 acres: one per street frontageParallel or double-sided if perpendicular to streetUnlockSec. 151.35
Model Home Sign5 ft including base16 sq ftAs close as possible to home1 per model homeAs close to the home as possible; orientation parallel or double-faced if perpendicular to streetUnlockSec. 151.36
Stake Sign (Commercial lot, construction interference)3 ft6 sq ft≥3 ft from curb/edge2 per tenantOn private property w/owner consent, min 3 ft from curb/edgeUnlockSec. 151.50(A)
Stake Sign (Single/two family or HOA)4 ft6 sq ft≥3 ft from curb/edge2 per lotPrivate property w/owner consent, min 3 ft from curb/edgeUnlockSec. 151.50(B)
Political Sign - Private Property8 ft36 sq ft≥3 ft from curb/edgeNot specifiedPrivate property w/owner consentUnlockSec. 151.51(A)

Transit Center District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Monument Sign4 ft15 sq ft15 ft from back of curb1 per lot1 per lot, 15 ft setback from back of curbUnlockSec. 151.54(C)(1)
Projecting Sign - Horizontal4 ft24 sq ft6 ft, not more than 12 in from building1 per street frontage or as approvedOn building, min 7.5 ft clearance from grade, not above roof/parapetUnlockSec. 151.54(C)(2)(a)
Projecting Sign - Vertical10 ft (≤2 stories); 15 ft (3 stories); 20 ft (4+ stories)24 sq ft (≤2 stories); 48 sq ft (3 stories); 72 sq ft (4+ stories)4.5 ft, not more than 12 in from building1 per street frontage or as approvedOn building, min 7.5 ft clearance from grade, not above 3rd storyUnlockSec. 151.54(C)(2)(b)
Wall Sign (Transit Center District)Not above roof line or parapetNot >200 sq ft per tenantNot >75% height and/or width of sign placement areaBy wall length and exceptions; tenant signage cap appliesOn the wall occupied by the business, as approvedUnlockSec. 151.54(C)(3)
Awning SignFront vertical edge: ≤1/3 overall awning height75% of height/width of vertical front edge for letters; 8 sq ft for logoNot specifiedFront vertical edge of awning; logo may be on sloped part (centered)UnlockSec. 151.54(C)(4)
Sandwich Board Sign4 ft8 sq ftMin 4 ft from curb, 4 ft sidewalk clear1 per businessOn sidewalks in TCD; min 4 ft from back of curb; min 4 ft clear sidewalk widthUnlockSec. 151.54(C)(7)
Ground Sign (Vacant Lot, TCD)6 ft16 sq ft (not wider/taller than 4 ft any dimension)4 ft1 per lot1 per lot; parallel or double faced if perpendicularUnlockSec. 151.54(C)(9)(a)
Ground Sign (Vacant Suite Window, TCD)48 in8 sq ft30 in1 per window/wall segmentInside one window per wall segment of vacant suiteUnlockSec. 151.54(C)(9)(b)

Area 1 (PD-169: Carroll Avenue addresses) (Single-Family Residential Districts), Area 3 (PD-169: 1017 Clint Street) (Single-Family Residential Districts), Single-Family Residential Districts, Single-Family Residential District (SF-12/20)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground Sign (Residential lot for sale/rent/lease)4 ft6 sq ft3 ft min from curb/edge2 per lotPrivate property, min 3 ft from curb/edgeUnlockSec. 151.50(B); 151.51
Political Sign8 ft36 sq ft3 ft min from curb/edgeNot specifiedPrivate property with consentUnlockSec. 151.51

PermitPal covers all 8 zoning districts in Carrollton — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 8 zones for Carrollton — start free

Prohibited Signs in Carrollton

  • Signs not expressly allowed pursuant to this chapter are prohibited.
  • Signs erected in a manner that may cause confusion, or obstruct the view or interpretation of any official traffic sign, signal or device.
  • Window signs, including painted window signs, except as expressly allowed in this chapter.
  • Any sign containing or displaying any obscene material.
  • Commercial billboards as defined in section 151.05 are prohibited.
  • Off-premises signs are prohibited except as otherwise allowed by Carrollton City Code, section 92.32.
  • Signs or material placed on or suspended from buildings, poles, sidewalks, vehicles and the like.
  • Placing or suspending from any building, light pole, utility pole, structure, sidewalk, parkway, driveway or parking area, any goods, wares, merchandise or other advertising or displaying of such items other than a sign, as defined, regulated and permitted by this code.
  • The attachment, suspension or hanging of cloth, paper, banner, flag, device or other similar matter to or on any sign, building, vehicle or structure, when the same shall create litter or a public nuisance.
  • Attaching any sign, paper or other material, or painting, stenciling, writing or similar or otherwise marking on any sidewalk, curb, gutter, street, service poles, utility poles or boxes, public property, fence or structure except as otherwise expressly allowed by ordinance.
  • No sign, whether required to be permitted or not, shall be illuminated to such an intensity or in such a manner, as to cause a glare of brightness to a degree that it constitutes a hazard or nuisance to traffic. Moving, flashing, blinking, intermittent lighted, changing color, beacons, revolving or similarly constructed signs shall not be allowed except for time and temperature on an otherwise permitted sign.
  • No lighted sign shall be erected within 150 feet of a residential district unless the lighting is shielded from view of the residential district.
  • No portion of any sign shall be erected on or over public property, unless the same is erected by the city, or with the permission of the city, or as specified in section 151.51(B).
  • Any sign erected on a vertical framework supported by and located immediately and entirely over the roof of a building is prohibited except as specified in section 151.34. Signs painted or attached on the roof of a structure are prohibited except as specified in sections 151.34 or 151.54.
  • No person shall erect, maintain or permit the erection of any balloon or other floating device anchored to the ground or to any structure within the city except as specified in section 151.38.
  • Stake signs, except as specified in section 151.50.
  • Portable signs, except as specified in section 151.52.
  • Sandwich board signs except as specified in section 151.54.
  • Freestanding self-supported advertising signs.
  • Sail or feather signs.
  • V-shaped signs.
  • Skid signs.
  • All signs visible from the exterior of a window shall be attached to the window or to the structure and shall comply with section 151.11(N).
  • Signs on residential lots are prohibited except as specified in sections 151.36, 151.50, and 151.51.
  • Windows where the back side of display shelving, storage or other fixtures is located adjacent to such windows. Windows shall be obscured up to four feet from grade with an opaque window film adhered to the window such that the back side of display shelving, storage or other fixture are not visible through the window. Foil, newspaper, cardboard and other such materials placed in windows shall be prohibited.
  • Awning signs are prohibited except as specified in section 151.54.
  • Can/box signs are prohibited on all buildings in Carrollton.
  • Pan signs are prohibited on retail buildings.
  • Signs painted directly on faces of buildings are prohibited except as specified in section 151.54.
  • No lighting shall be permitted to outline individual windows.
  • No lighting shall be permitted to outline an individual occupancy in a multitenant building.
  • No lighting shall be permitted to outline any accessory structures, signs, light poles or other appurtenances onsite.
  • No lighting shall be permitted to outline any vertical features of the building separate from the roof line (except rope or other continuous or connected series of lights utilized to outline only the roof line).

Exempt Signs in Carrollton

  • One temporary banner not exceeding eight square feet in area shall be allowed for the period of time the suite or building on which such sign is located is available for sale, rental or lease, but in no event for longer than 180 days per calendar year.
  • Nameplates, memorial plaques, building identification signs and building cornerstones not exceeding two square feet in area when cut or carved into the masonry surface or when made of noncombustible material and made an integral part of the building or structure.
  • Permanent onsite signs limited to: (a) one sign at a drive-through lane entrance, maximum 3 feet in height and 4 square feet in area; (b) one sign at a drive-through lane exit, maximum 3 feet in height and 4 square feet in area, both located behind the required front building setback.
  • Multitenant buildings: one sign with a maximum area of 20 square feet, height of 5 feet, setback as required by zoning, tenant panels maximum 4 inches tall, same size and color font, one panel per tenant, decorative metal or similar durable material.
  • Legal notices or warning signs posted in compliance with state or federal law including criminal trespass warning signs, open carry signs, and disabled parking signs.
  • Designated parking space signs no larger than 12 inches by 18 inches with a maximum overall height of 7 feet.
  • Temporary signs warning of a particularly dangerous or hazardous condition containing only sufficient information to warn of such danger or condition.
  • Scoreboards, golf course tee signs, and athletic field identification signs.
  • Athletic field fencing signs facing into an athletic field intended to be visible only from inside the field, and no taller than the fence or wall upon which the sign is located.
  • Signs fabricated into windscreens for tennis courts on City of Carrollton park facilities only for identification purposes.
  • Sculptures when installed in compliance with the comprehensive zoning ordinance and construction codes.
  • The changing of messages or copy on signs designed and intended to be changed on a regular basis provided the sign is not altered (e.g. theater marquees, electronic reader boards, menus, fuel prices, billboards, directories).
  • The removal and replacement of interchangeable panels for signs designed and approved for this specific purpose.
  • Window signs/painted window signs with a maximum size not exceeding 25 percent of the total window area for any linear wall segment; limited to one- or two-story retail buildings or the ground floor of a mixed-use building with retail at the ground floor. Blinking signs are prohibited.
  • Gasoline/service station informational signage: signs located beneath a canopy are exempt; governmentally mandated signage and signage contained within the individual pumps are also exempt; 10 square feet of signage is permitted per side under the canopy per set of dispensers; signage beneath the canopy not intended to be read from the public right-of-way is exempt; letters less than 3 inches height not counted as part of sign allowance.
  • Incidental signs as defined in section 151.05, limited to one per building entrance.
  • Banners in conjunction with an approved special event permit as provided in section 151.39.
  • Stake signs as provided in section 151.50.
  • Political signs as provided in section 151.51.
  • Portable and vehicle signs as provided in section 151.52.
  • Flags and flagpoles as provided in section 151.53.
  • Sandwich board signs as provided in section 151.54.

Sign Plan & Submission Notes for Carrollton

  • A sign permit is required for all signs unless exempted; see Sec. 151.10 and Sec. 151.11.
  • The Development Services Department approves all signs for multiple-tenant and multiple-building lot-coordinated signage for design compatibility. (Sec. 151.10(B))
  • The Building Official may require the filing of plans or other pertinent information for a sign permit application. Standard plans may be filed with the Building Official. (Sec. 151.13)
  • In the Transit Center District (Sec. 151.54), all signs requiring a permit must first obtain Development Plan approval prior to issuance of a permit. The development plan must be approved by the City Manager or designee and must include site plan, building elevations, sign copy/dimensions, setbacks, materials, illumination details.
  • Denial of a Transit Center District Development Plan may be appealed to the Property Standards Board if filed within 10 days.
  • For PD-169, multiple-building lot-coordinated signage is considered in accordance with section 151.10(B). (Sec. 151.55; see also 151.10(B))
  • Variances and special exceptions to sign code provisions are handled by the Board of Adjustment. This includes appeals, alternative materials/methods, nonconforming sign reconstruction, hardship cases (Sec. 151.81 and following). Public hearing and notice required.
  • Variances apply only where literal enforcement would result in an unnecessary hardship not self-created nor for financial reasons alone, and cannot permit prohibited signs or acts.
  • Meritorious exceptions for innovative or visually beneficial signage proposals may be considered by the Board of Adjustment.

Source: municode municipal code