Sign TypeMax HeightMax AreaSetback
Human SignNot listedNot listedNot in ROW.
Directional Sign3 ft5 sq ftNot listed
Menu Sign8 ft32 sq ftNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Flower MoundPartial Coverage

Sign Types Covered

29

  • Directional Sign
  • Projected Sign
  • Billboard
  • Portable Sign
  • +2 more types

Zoning Districts

5

Different zoning districts with specific sign regulations

Data Includes

  • Height restrictions
  • Illumination rules

Official Resources for Flower Mound

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Flower Mound, the height limit for Ground Sign (Church) in the Residential zones is 10 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

From the submission notes on this page: Application for a comprehensive sign package must include a description, scaled drawings, a site plan, legal description, and is subject to public hearing/review by the planning and zoning commission and town council. Run a code check for an exact address to see the permit requirements for that zone.

Flower Mound's sign code covers 29 sign types, including Directional Sign, Projected Sign, Billboard, and Portable Sign. The ordinance lists 18 exemptions. One of them: No permit is required for wall signs showing only the name and address of the owner or occupant, not exceeding six square feet in area. The full list is on this page.

In Flower Mound, Ground Sign (Church) in the Residential zones must be set back 15 ft from right-of-way. The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Flower Mound's sign ordinance that cover digital, changing, or flashing signs: Nuisance signs with moving parts, animated features, flashing, blinking or rotating illumination, or other distracting visual/audible features are prohibited. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Flower Mound Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Flower Mound, Texas, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Flower Mound, Texas Sign Rules at a Glance

Flower Mound, Texas regulates 29 sign types across 5 zoning districts. Menu Signs are capped at 8 ft tall and 32 sq ft (Sec. 86-64).

Detailed Sign Ordinance Requirements for Flower Mound, Texas

Sign Rules by Zoning District in Flower Mound (5 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones148 ft32 sq ftNot listed
A agricultural district215 ft48 sq ftNot listed
WR water recreation district120 ft24 sq ftNot listed
Residential zones525 ft (flagpole)60 sq ft/side (double-faced)Not listed
Nonresidential zones940 ft (flagpole)300 sq ftNot listed

Zone-by-Zone Sign Requirements in Flower Mound(sample of 3 of 5 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Projected SignNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlockSec. 86-4(1)
BillboardNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlockSec. 86-4(2)
Portable SignNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlockSec. 86-4(3)
SearchlightNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlockSec. 86-4(4)
Vehicular SignNot listedNot listedNot listedNot listedNot listedProhibited on vehicles parked to advertise and be visible from ROW (see exceptions).Not listedUnlockSec. 86-4(5)
Human SignNot listedNot listedNot listedNot in ROW.Not listedOn-premises only for fundraising event.Not listedUnlockSec. 86-4(17); Sec. 86-72
Directional Sign3 ft5 sq ftNot listedNot listedNot listedPrivate property, over doorways or entrances allowed.Not listedUnlockSec. 86-63
Menu Sign8 ft32 sq ftNot listedNot listedNot listedDrive-through windows; oriented away from public street.Not listedUnlockSec. 86-64

Residential zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground Sign (Church)10 ft60 sq ft/side (double-faced)10 ft15 ft from ROW; 120 ft from other ground signs; 60 ft from property lines of any other lot.See code (generally 1 per street frontage, secondary sign name/address/logo only)On property of the churchNot listedUnlockSec. 86-67(1)-(5), (9a), (7)
Ground Sign (School)10 ft60 sq ft/side (double-faced)10 ft15 ft from ROW; 120 ft from other ground signs; 60 ft from property lines of any other lot.1 per street frontage if <1000 ft, 2 signs if frontage ≥1000 ft (min 700 ft apart), plus one small monument sign ≤19.2 sq ft/face >200 ft from other signOn school propertyNot listedUnlockSec. 86-67(1)-(5), (9b), (9c), (7), (12)
Wall Sign (Single Family/Duplex Lot)Not listed3 sq ft (<1 acre), 6 sq ft (≥1 acre)Not listedNot listed1 per lotOn dwellingNot listedUnlockSec. 86-108
Residential Subdivision Wall SignNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlockSec. 86-109
Flag (Residential)25 ft (flagpole)15 sq ft per flagNot listedNot listedMax 3 flagpolesOn private lotNot listedUnlockSec. 86-104(2)

Nonresidential zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground Sign (Nonresidential)10 ft60 sq ft/side (double-faced)10 ft15 ft from ROW; 120 ft from other ground signs; 60 ft from other property lines1 per street frontage, max 2On property of nonresidential useNot listedUnlockSec. 86-67(1)-(8), (13)
Wall Sign (Nonresidential Tenant)Varies by linear frontage (see below)300 sq ftVaries by linear frontage (see below)Not listed1 per tenant (plus extras per code for corner/end/etc.)Attached to building wall, mansard roof (≥60° slope), or screening wall; not above roofline or wall; not closer than 1 ft to edge of store frontNot listedUnlockSec. 86-68(a)(1)-(7), (b)
Building Identification Wall SignSee chart below150 sq ftUp to 25% of linear footage, see belowNot listedNot listedPrimary building wall, designed focal point, at least 5 ft from other sign on same wallNot listedUnlockSec. 86-68(b)(5)
Window SignNot listed20% of window areaNot listedNot listedNot listedWindow of commercial frontNot listedUnlockSec. 86-69; Sec. 86-62
Awning SignLettering: 8 in; Commercial image: max 3 ftNot to exceed total sign area allowed for wall signs (see wall sign rules)Commercial image: max 4 ftNot listed1 per main entrance, plus 1 for cornerOn slope portion of awning, centered over main entrance (one allowed; second allowed for corner with side wall awning)Not listedUnlockSec. 86-70(a)
Canopy SignNot listedMust adhere to wall sign maximumsNot listedNot listedNot listedAttached to permanent overhead roof projectionNot listedUnlockSec. 86-70(b)
Directional Sign3 ft5 sq ftNot listedNot listedNot listedPrivate property, over doorways or entrances allowed.Not listedUnlockSec. 86-63
Flag (Nonresidential)40 ft (flagpole)40 sq ft per flagNot listedNot listedMax 3 flagpolesOn private lotNot listedUnlockSec. 86-104(3)

PermitPal covers all 5 zoning districts in Flower Mound. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Flower Mound

  • Signs projected more than 12 inches from a facade, wall, fence, roof or other principal means of support are prohibited.
  • Billboards (large, off-premises outdoor advertising signs used for product advertisement) are prohibited.
  • Portable signs, including those on portable or movable frames or structures not affixed to the ground, are prohibited unless specifically addressed in the ordinance.
  • Searchlights used to attract attention to a business or location are prohibited.
  • Vehicular signs on or affixed to vehicles/trailers parked so as to be visible from the public right-of-way and used for advertising are prohibited, except where incidental to the primary use of the vehicle.
  • Balloons or inflatable devices used as signs or advertisements are prohibited except as allowed for grand opening signs.
  • Pole mounted flags or banners used to attract attention to a business or location are prohibited except as provided for 'coming soon', 'now open', 'grand opening', 'now hiring', 'change of business/ownership', or public announcement signs, and not including flags permitted by section 86-104.
  • Nuisance signs with moving parts, animated features, flashing, blinking or rotating illumination, or other distracting visual/audible features are prohibited.
  • Illegal or unlawful signs are prohibited, including: signs with obscene/indecent content; signs imitating government signs; signs blocking access, visibility or utilities; signs placed on utility poles, fire hydrants, trees, etc.; unauthorized markings on streets/sidewalks/buildings; permanent signs in the public right-of-way; signs in violation of this section; unsafe, abandoned or dilapidated signs.
  • V-shaped signs (two panels in a V when viewed from above) are prohibited.
  • Signs may not be illuminated so as to cause glare or hazards/nuisance to traffic; indirect lighting shall not overshoot the sign facade.
  • Unshielded neon signs are prohibited except as allowed in section 86-69.
  • Pole signs erected before adoption of the ordinance must be removed when the property changes zoning, ownership, or business name or becomes unsafe, and then must comply with current standards.
  • Off-premises signs are prohibited except as provided in specific code sections.
  • No person shall attach, paint, stencil or write any sign (other than physical address) on walls, railings, fences, sidewalks, curbs, gutters, streets, utility poles, public buildings, or structures unless otherwise allowed in the code.
  • No sign is permitted on architectural features such as cupolas, towers, domes, parapet walls, or other aesthetic elements unless the sign is less than 10 feet from the roof line.
  • Human signs are prohibited except as specifically allowed.

Exempt Signs in Flower Mound

  • No permit is required for wall signs showing only the name and address of the owner or occupant, not exceeding six square feet in area.
  • No permit is required for interior signs located inside a building (note: not within ten feet of the storefront window if visible outside).
  • No permit is required for small directional signs (up to five square feet, three feet in height) on private property for the convenience of the public.
  • No permit is required for menu signs at drive-through food service windows, up to 32 square feet and eight feet in height, not oriented toward the public street.
  • No permit is required for ball field fencing signs used for recreation program fundraising, subject to limitations (interior-facing only, under eight feet, etc.).
  • No permit is required for temporary fuel-price or credit card signs placed on pump islands, subject to specific requirements.
  • No permit is required for temporary informational signs required for land use or zoning plan change public notices.
  • No permit is required for work in progress signs identifying work in progress, subject to size, height, and timing restrictions.
  • No permit is required for official signs required or authorized by local, state, federal government or agencies (traffic, utility, air traffic control, required notices, etc.).
  • No permit is required for signs for personal or individual use, such as garage/yard/estate sales, private ownership, or danger notices, within size, placement and timing limits.
  • No permit is required for memorial signs, plaques, markers, etc. when integral to a building or landscape.
  • No permit is required for public/private flag poles displaying state, national, local, religious, institutional flags, emblems, or registered corporate logo flags within limits.
  • No permit is required for holiday decorations displayed in a temporary manner on or around holidays.
  • No permit is required for political signs in connection with an upcoming election, subject to requirements.
  • No permit is required for public announcement signs by charitable, religious, philanthropic, educational or civic institutions, subject to time, place, size and height restrictions.
  • No permit is required for a wall sign identifying the family name, property name or street address on single-family or duplex lots, within size limits.
  • No permit is required for residential subdivision wall signs, provided they are approved through the subdivision site plan process.
  • No permit is required for human signs, though their use is otherwise generally prohibited except for qualifying charitable/religious/civic fund-raising events (subject to restrictions).

Sign Plan & Submission Notes for Flower Mound

  • A comprehensive sign package ('sign plan') is required for all nonresidential development, including multifamily. Specialized review of residential signs occurs through a planned development or subdivision site plan exception.
  • Application for a comprehensive sign package must include a description, scaled drawings, a site plan, legal description, and is subject to public hearing/review by the planning and zoning commission and town council.
  • Residential subdivision wall signs must be approved by the planning and zoning commission, and town council if required, as part of the subdivision site plan.

Source: municode municipal code