Sign Regulations in Hurst, Texas

Hurst, Texas has specific sign regulations covering 21 sign types across 14 zoning districts. Regulated sign types include Wall Sign, Single-Tenant Monument Sign, Multi-Tenant Monument Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Hurst, Texas

Sample Sign Requirements in Hurst

Sign TypeMax HeightMax AreaSetback
Wall Sign (Conditional Use - Church/Public Building/School)80 sq. ft.
Monument Sign (Conditional Use - Church/Public Building/School)8 ft.50 sq. ft. per side
Temporary Home Sales Office Sign8 sq. ft.

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for HurstFull Coverage

Sign Types Covered

21

  • Wall Sign
  • Single-Tenant Monument Sign
  • Multi-Tenant Monument Sign
  • Freeway Pole Sign
  • +2 more types

Zoning Districts

14

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Hurst

Frequently Asked Questions

In Hurst, monument signs are limited to 8 ft.. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Hurst, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Hurst, regulated sign types include Wall Sign, Single-Tenant Monument Sign, Multi-Tenant Monument Sign, Freeway Pole Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Hurst vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Hurst are regulated with specific requirements for brightness, animation, and message duration. Hurst has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Hurst Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Hurst, Texas sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Hurst, Texas Sign Rules at a Glance

Hurst, Texas regulates 21 sign types across 14 zoning districts. Single-Tenant Monument Signs in the R-1A Proposed Duplex Zoning District (R-1A), R-2 Dwelling District (R-2), R-3 Dwelling District (R-3), RH Retirement Housing District (RH), AL Assisted Living District (AL), MH Mobile Home District (MH) zoning district are capped at 6 ft. tall and 50 sq. ft. per face, with a At least 15 ft. from curb; 20 ft. from residential property setback (Sec. Sec. 27-22(x) Table, Sec. 27-22(j)(4); applies to R-3, RH, AL, MH). Most commercial signs in Hurst require a permit.

Detailed Sign Ordinance Requirements for Hurst, Texas

Sign Rules by Zoning District in Hurst (14 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
R-1 Dwelling District (R-1), RE-1 Dwelling District (RE-1), RE-2 Dwelling District (RE-2)48 ft.80 sq. ft.
R-1A Proposed Duplex Zoning District (R-1A), R-2 Dwelling District (R-2), R-3 Dwelling District (R-3), RH Retirement Housing District (RH), AL Assisted Living District (AL), MH Mobile Home District (MH)412 ft.50 sq. ft. per face
O-1 Office District (O-1), O-2 Office District (O-2)26 ft.50 sq. ft. per face
U School, Church and Institution District (U)26 ft.80 sq. ft.
NB Neighborhood Business District (NB), Limited Business District (LB)26 ft.50 sq. ft. per face
GB General Business District (GB), O-C Outdoor Commercial District (O-C)620 ft. above freeway grade200 sq. ft. per side
TX 10 Texas Highway 10 Multiuse District (TX-10)320 ft. above freeway grade200 sq. ft. per face
TC Town Center District (TC)450 ft. (only on properties with direct SH 183 frontage, within 50 ft. of r-o-w)200 sq. ft. per building side
Mixed-Use Planned Development Overlay District (MU-PD, MU-SPUD)2Top of parapet wall or roof eave
PD Planned Development District (PD)1As approved by PD site plan, subject to underlying base district unless modified
R-PS Residential-Performance Standard District (R-PS)2Top of parapet wall or roof eave40 sq. ft.
FP Floodplain District (FP)1Based on base districtUp to size allowed by base district
Interim Zoning District (IZ)1As limited or allowed by approval of interim use/site plan
General Regulations For All Zones2Varies by type (see summary table at 27-22(x))Company logo max 100 sq. ft.

Zone-by-Zone Sign Requirements in Hurst(sample of 3 of 14 zones)

R-1A Proposed Duplex Zoning District (R-1A), R-2 Dwelling District (R-2), R-3 Dwelling District (R-3), RH Retirement Housing District (RH), AL Assisted Living District (AL), MH Mobile Home District (MH)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignTop of parapet wall or roof eave height40 sq. ft.Multiple signs allowed per building per frontageOn building, per districtUnlockSec. 27-22(x) Table of permitted signs and 27-22(j)(1)
Single-Tenant Monument Sign6 ft.50 sq. ft. per faceAt least 15 ft. from curb; 20 ft. from residential propertyOne per lotIn front yard, at least 15 ft. from curb and 20 ft. from residential propertyUnlockSec. 27-22(x) Table, Sec. 27-22(j)(4); applies to R-3, RH, AL, MH
Multi-Tenant Monument Sign12 ft.20 sq. ft. per business per side (40 sq. ft. for anchor), up to 140 sq. ft. totalAt least 15 ft. behind curb, 100 ft. from another monument/pole signOne per street frontageIn front, spacing and landscaping requiredUnlockSec. 27-22(x) Table; 27-22(j)(5)
Menu Board6 ft.45 sq. ft.1 menu board per businessFreestanding or wall mounted within a drive-through or businessUnlockSec. 27-22(x) Table, 27-22(j)(7)

GB General Business District (GB), O-C Outdoor Commercial District (O-C)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign (Front Elevation)Top of parapet wall or roof eaveMultiple per frontageOn building; parallel to faceUnlockSec. 27-22(x), 27-22(j)(1)
Wall Sign (Rear Elevation on Street)Top of parapet wall or roof eaveMultiple per eligible rear elevationOn building rear that fronts on street or internal roadUnlockSec. 27-22(j)(1)4
Wall Sign (Side Elevation on Street)Top of parapet wall or roof eaveMultiple per eligible side elevationOn building side that fronts on street or internal roadUnlockSec. 27-22(j)(1)5
Single-Tenant Monument Sign6 ft.50 sq. ft. per face15 ft. from curb, 20 ft. from residential propertyOne per lotFront yard, outside required setbacksUnlockSec. 27-22(j)(4)
Multi-Tenant Monument Sign12 ft.20 sq. ft. per business, 40 sq. ft. for anchor tenant, max 140 sq. ft. per face15 ft. behind curb, 100 ft. from another monument signOne per street frontageFront yard, outside required setbacksUnlockSec. 27-22(j)(5)
Freeway Pole Sign20 ft. above freeway grade200 sq. ft. per side15 ft. behind curbOne per street frontageFrontage on Loop 820 or US Hwy 183/121, 15 ft. behind curb, 100 ft. from residential propertyUnlockSec. 27-22(j)(6)

TX 10 Texas Highway 10 Multiuse District (TX-10)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignTop of parapet wall or roof eaveMultiple per qualifying elevationOn building; parallel to building faceUnlockSec. 27-22(x) Table; see also TX-10 section for reference
Monument Sign6 ft.50 sq. ft. per face15 ft. behind curb, 20 ft. from residential propertyOne per street frontageFront yard, with required setbacksUnlockSec. 27-22(j)(4), TX-10
Freeway Pole Sign20 ft. above freeway grade200 sq. ft. per face15 ft. behind curbOne per street frontageFrontage on Loop 820 or US Hwy 183/121UnlockSec. 27-22(j)(6), TX-10

PermitPal covers all 14 zoning districts in Hurst — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 14 zones for Hurst — start free

Prohibited Signs in Hurst

  • No sign shall be erected, altered, or added to unless it conforms to the provisions contained in the sign regulations.
  • No sign shall be located in the public right-of-way or on public property unless approved in a planned development site plan.
  • No more than two sign faces (sides) are allowed per sign.
  • No permanent wood signs shall be allowed.
  • All sign structures must be painted or anodized to blend with the architecture; exposed metal surfaces subject to rust or corrosion are prohibited.
  • Fluorescent colors and fluorescent painted letters are not to be used on signs except for electric neon window signs as allowed.
  • No sign may be erected so as to interfere with fire escapes, exits, standpipes, windows, ventilators, doors, or stairs.
  • Minimum of 50 feet of street frontage required for ground signs, unless otherwise approved in a planned development site plan.
  • A sign shall not be constructed within or project over any property line, vehicular right-of-way line, or public/private utility or drainage easement without an approved encroachment letter, unless otherwise approved in a mixed use or planned development district.
  • No sign, fence, wall, shrub, or other structure shall be erected that obstructs visibility triangles for drivers.
  • All temporary signs not specifically allowed are prohibited.
  • The following sign types are expressly prohibited: roof signs, rotating/flashing/blinking/moving/animated signs, private signs on public property, signs attached to utility poles/fences/trees, visual depiction of sexual areas of human form, use of the words 'topless', 'bottomless', 'naked' on signs, off-premises advertising signs (unless compliant with regulations/PDS), and any sign not specifically permitted.
  • Electronic/digital signs shall not: display animation, moving video, scrolling, flashing, blinking, flying or chasing text or graphics; or create any sense of motion. Only static display with a minimum 30-second duration per image.
  • Lettering for stand-alone electronic signs limited to amber on black; fluorescent lettering is prohibited.
  • Electronic/digital signs must be automatically dimmed after dark and not exceed specified luminance requirements.
  • No sign or lighting shall be authorized that, by placement or operation, causes distress, discomfort, or injury to persons on adjacent property or interferes with their reasonable use.
  • No sign shall duplicate the colors, characteristics, or symbols of traffic signs/signals, or otherwise create confusion for drivers.
  • No sign shall be structurally altered to prolong its life or change shape/size or type if nonconforming.
  • No sign shall be re-established after damage/destruction exceeding 25% (or 50%, see nonconformance provisions) of replacement cost without compliance.
  • Lighting and electronics shall not be added to nonconforming signs, unless approved by site plan.

Exempt Signs in Hurst

  • Government-owned traffic signals and markings, and any sign required by law, are exempt.
  • The following signs are exempt from permitting (although they must comply with regulations): public notice or warning signs required by law, signs located inside a building not visible from outside, works of art without commercial messages, utility/safety signs not exceeding 1 sq. ft., railway property signs referencing railway operation, security warning or neighborhood watch signs under 2 sq. ft., on-premises residential real estate signs, political signs, and garage sale signs.
  • Residential real estate signs, garage sale signs, and political signs do not require a permit if compliant with criteria outlined in the section.
  • Gasoline price-per-gallon or credit card signs mounted on pump islands do not require a permit, but must comply with size and placement regulations.
  • No permit is required for U.S., Texas, or City of Hurst flags, or for pennants used in grand opening signage, or for window signs inside the glass, or advertising on benches at transit stops.
  • Charity/civic event signs do not require a permit fee.
  • Bench signs do not require a permit if installed at designated public transportation stops.

Sign Plan & Submission Notes for Hurst

  • A planned development (PD) site plan is required for approval of any sign that varies from the strict application of the sign regulations (e.g., signs in public right-of-way, modifications to sign standards, special exceptions, sign variance).
  • All new (or renovated/reconstructed) developments within the Town Center District require site plan approval (Sec. 27-15.2(i)).
  • All development sites within the Town Center District must be submitted, reviewed, and approved as planned developments in accordance with section 27-16. Any planned development created within the TC district must adhere to regulations unless otherwise stipulated by the PD ordinance.
  • A site plan is required prior to construction/reconstruction of any development in districts requiring one (including all mixed-use and PD/overlay districts).
  • A landscape plan, including sign location, size, height, orientation, and design, must be included with site plan review for certain zoning districts (see, e.g., RH Retirement Housing, AL Assisted Living, TX 10 Highway and Town Center districts).
  • All uses within the RH Retirement Housing and AL Assisted Living districts require site plan approval, which must include the location, size, height, orientation, and design of all signs.
  • A certificate of site plan approval is required prior to the issuance of any building permit for alterations, additions, or new signage on Historic Landmark properties (Sec. 27-15.3(e)).
  • In Mixed-Use (MU) Planned Development Overlay District, a site plan is required for all PD or SPUD properties; non-mixed-use proposals or single-use building projects must submit for a conditional use permit and request modifications via the site plan process.
  • A master sign plan or specific signage details may be a requirement of a planned development site plan whenever signage deviates from base district requirements.
  • Sign variances or special exceptions may only be granted after a public hearing by the zoning board of adjustment; an application and site plan are typically required for such cases.

Source: municode municipal code