Sign Regulations in Hurst, Texas
Hurst, Texas has specific sign regulations covering 21 sign types across 14 zoning districts. Regulated sign types include Wall Sign, Single-Tenant Monument Sign, Multi-Tenant Monument Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 8, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Hurst, Texas
Sample Sign Requirements in Hurst
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign (Conditional Use - Church/Public Building/School) | Not listed | 80 sq. ft. | Not listed |
| Monument Sign (Conditional Use - Church/Public Building/School) | 8 ft. | 50 sq. ft. per side | Not listed |
| Temporary Home Sales Office Sign | Not listed | 8 sq. ft. | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
21
- Wall Sign
- Single-Tenant Monument Sign
- Multi-Tenant Monument Sign
- Freeway Pole Sign
- +2 more types
Zoning Districts
14
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Hurst
Other Cities in Texas
Frequently Asked Questions
In Hurst, the height limit for Freeway Pole Sign in the GB General Business District (GB), O-C Outdoor Commercial District (O-C) is 20 ft above freeway grade (Sec. 27-22(j)(6)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Hurst require a permit. From the submission notes on this page: A planned development (PD) site plan is required for approval of any sign that varies from the strict application of the sign regulations (e.g., signs in public right-of-way, modifications to sign standards, special exceptions, sign variance). Run a code check for an exact address to see the permit requirements for that zone.
Hurst's sign code covers 21 sign types, including Wall Sign, Single-Tenant Monument Sign, Multi-Tenant Monument Sign, and Freeway Pole Sign. Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Residential real estate signs, garage sale signs, and political signs do not require a permit if compliant with criteria outlined in the section. The full list is on this page.
In Hurst, Single-Tenant Monument Sign in the GB General Business District (GB), O-C Outdoor Commercial District (O-C) must be set back 15 ft from curb, 20 ft from residential property (Sec. 27-22(j)(4)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Hurst's sign ordinance that cover digital, changing, or flashing signs: Electronic/digital signs shall not: display animation, moving video, scrolling, flashing, blinking, flying or chasing text or graphics; or create any sense of motion. Only static display with a minimum 30-second duration per image. Lettering for stand-alone electronic signs limited to amber on black; fluorescent lettering is prohibited. Electronic/digital signs must be automatically dimmed after dark and not exceed specified luminance requirements. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Hurst Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Hurst, Texas, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Hurst, Texas Sign Rules at a Glance
Hurst, Texas regulates 21 sign types across 14 zoning districts. Freeway Pole Signs in the GB General Business District (GB), O-C Outdoor Commercial District (O-C) are capped at 20 ft above freeway grade and 200 sq ft per side, set back 15 ft behind curb (Sec. 27-22(j)(6)). Most commercial signs in Hurst require a permit.
Detailed Sign Ordinance Requirements for Hurst, Texas
Sign Rules by Zoning District in Hurst (14 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| R-1 Dwelling District (R-1), RE-1 Dwelling District (RE-1), RE-2 Dwelling District (RE-2) | 4 | 8 ft. | 80 sq. ft. | Not listed |
| R-1A Proposed Duplex Zoning District (R-1A), R-2 Dwelling District (R-2), R-3 Dwelling District (R-3), RH Retirement Housing District (RH), AL Assisted Living District (AL), MH Mobile Home District (MH) | 4 | 12 ft. | 50 sq. ft. per face | Not listed |
| O-1 Office District (O-1), O-2 Office District (O-2) | 2 | 6 ft. | 50 sq. ft. per face | Not listed |
| U School, Church and Institution District (U) | 2 | 6 ft. | 80 sq. ft. | Not listed |
| NB Neighborhood Business District (NB), Limited Business District (LB) | 2 | 6 ft. | 50 sq. ft. per face | Not listed |
| GB General Business District (GB), O-C Outdoor Commercial District (O-C) | 6 | 20 ft. above freeway grade | 200 sq. ft. per side | Not listed |
| TX 10 Texas Highway 10 Multiuse District (TX-10) | 3 | 20 ft. above freeway grade | 200 sq. ft. per face | Not listed |
| TC Town Center District (TC) | 4 | 50 ft. (only on properties with direct SH 183 frontage, within 50 ft. of r-o-w) | 200 sq. ft. per building side | Not listed |
| Mixed-Use Planned Development Overlay District (MU-PD, MU-SPUD) | 2 | Top of parapet wall or roof eave | Not listed | Not listed |
| PD Planned Development District (PD) | 1 | Not listed | As approved by PD site plan, subject to underlying base district unless modified | Not listed |
| R-PS Residential-Performance Standard District (R-PS) | 2 | Top of parapet wall or roof eave | 40 sq. ft. | Not listed |
| FP Floodplain District (FP) | 1 | Based on base district | Up to size allowed by base district | Not listed |
| Interim Zoning District (IZ) | 1 | Not listed | As limited or allowed by approval of interim use/site plan | Not listed |
| General Regulations For All Zones | 2 | Varies by type (see summary table at 27-22(x)) | Company logo max 100 sq. ft. | Not listed |
Zone-by-Zone Sign Requirements in Hurst(sample of 3 of 14 zones)
R-1A Proposed Duplex Zoning District (R-1A), R-2 Dwelling District (R-2), R-3 Dwelling District (R-3), RH Retirement Housing District (RH), AL Assisted Living District (AL), MH Mobile Home District (MH)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Top of parapet wall or roof eave height | 40 sq. ft. | Not listed | Not listed | Multiple signs allowed per building per frontage | On building, per district | Not listed | Unlock | Sec. 27-22(x) Table of permitted signs and 27-22(j)(1) |
| Single-Tenant Monument Sign | 6 ft. | 50 sq. ft. per face | Not listed | At least 15 ft. from curb; 20 ft. from residential property | One per lot | In front yard, at least 15 ft. from curb and 20 ft. from residential property | Not listed | Unlock | Sec. 27-22(x) Table, Sec. 27-22(j)(4); applies to R-3, RH, AL, MH |
| Multi-Tenant Monument Sign | 12 ft. | 20 sq. ft. per business per side (40 sq. ft. for anchor), up to 140 sq. ft. total | Not listed | At least 15 ft. behind curb, 100 ft. from another monument/pole sign | One per street frontage | In front, spacing and landscaping required | Not listed | Unlock | Sec. 27-22(x) Table; 27-22(j)(5) |
| Menu Board | 6 ft. | 45 sq. ft. | Not listed | Not listed | 1 menu board per business | Freestanding or wall mounted within a drive-through or business | Not listed | Unlock | Sec. 27-22(x) Table, 27-22(j)(7) |
GB General Business District (GB), O-C Outdoor Commercial District (O-C)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (Front Elevation) | Top of parapet wall or roof eave | Not listed | Not listed | Not listed | Multiple per frontage | On building; parallel to face | Not listed | Unlock | Sec. 27-22(x), 27-22(j)(1) |
| Wall Sign (Rear Elevation on Street) | Top of parapet wall or roof eave | Not listed | Not listed | Not listed | Multiple per eligible rear elevation | On building rear that fronts on street or internal road | Not listed | Unlock | Sec. 27-22(j)(1)4 |
| Wall Sign (Side Elevation on Street) | Top of parapet wall or roof eave | Not listed | Not listed | Not listed | Multiple per eligible side elevation | On building side that fronts on street or internal road | Not listed | Unlock | Sec. 27-22(j)(1)5 |
| Single-Tenant Monument Sign | 6 ft. | 50 sq. ft. per face | Not listed | 15 ft. from curb, 20 ft. from residential property | One per lot | Front yard, outside required setbacks | Not listed | Unlock | Sec. 27-22(j)(4) |
| Multi-Tenant Monument Sign | 12 ft. | 20 sq. ft. per business, 40 sq. ft. for anchor tenant, max 140 sq. ft. per face | Not listed | 15 ft. behind curb, 100 ft. from another monument sign | One per street frontage | Front yard, outside required setbacks | Not listed | Unlock | Sec. 27-22(j)(5) |
| Freeway Pole Sign | 20 ft. above freeway grade | 200 sq. ft. per side | Not listed | 15 ft. behind curb | One per street frontage | Frontage on Loop 820 or US Hwy 183/121, 15 ft. behind curb, 100 ft. from residential property | Not listed | Unlock | Sec. 27-22(j)(6) |
TX 10 Texas Highway 10 Multiuse District (TX-10)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Top of parapet wall or roof eave | Not listed | Not listed | Not listed | Multiple per qualifying elevation | On building; parallel to building face | Not listed | Unlock | Sec. 27-22(x) Table; see also TX-10 section for reference |
| Monument Sign | 6 ft. | 50 sq. ft. per face | Not listed | 15 ft. behind curb, 20 ft. from residential property | One per street frontage | Front yard, with required setbacks | Not listed | Unlock | Sec. 27-22(j)(4), TX-10 |
| Freeway Pole Sign | 20 ft. above freeway grade | 200 sq. ft. per face | Not listed | 15 ft. behind curb | One per street frontage | Frontage on Loop 820 or US Hwy 183/121 | Not listed | Unlock | Sec. 27-22(j)(6), TX-10 |
PermitPal covers all 14 zoning districts in Hurst. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Hurst
- No sign shall be erected, altered, or added to unless it conforms to the provisions contained in the sign regulations.
- No sign shall be located in the public right-of-way or on public property unless approved in a planned development site plan.
- No more than two sign faces (sides) are allowed per sign.
- No permanent wood signs shall be allowed.
- All sign structures must be painted or anodized to blend with the architecture; exposed metal surfaces subject to rust or corrosion are prohibited.
- Fluorescent colors and fluorescent painted letters are not to be used on signs except for electric neon window signs as allowed.
- No sign may be erected so as to interfere with fire escapes, exits, standpipes, windows, ventilators, doors, or stairs.
- Minimum of 50 feet of street frontage required for ground signs, unless otherwise approved in a planned development site plan.
- A sign shall not be constructed within or project over any property line, vehicular right-of-way line, or public/private utility or drainage easement without an approved encroachment letter, unless otherwise approved in a mixed use or planned development district.
- No sign, fence, wall, shrub, or other structure shall be erected that obstructs visibility triangles for drivers.
- All temporary signs not specifically allowed are prohibited.
- The following sign types are expressly prohibited: roof signs, rotating/flashing/blinking/moving/animated signs, private signs on public property, signs attached to utility poles/fences/trees, visual depiction of sexual areas of human form, use of the words 'topless', 'bottomless', 'naked' on signs, off-premises advertising signs (unless compliant with regulations/PDS), and any sign not specifically permitted.
- Electronic/digital signs shall not: display animation, moving video, scrolling, flashing, blinking, flying or chasing text or graphics; or create any sense of motion. Only static display with a minimum 30-second duration per image.
- Lettering for stand-alone electronic signs limited to amber on black; fluorescent lettering is prohibited.
- Electronic/digital signs must be automatically dimmed after dark and not exceed specified luminance requirements.
- No sign or lighting shall be authorized that, by placement or operation, causes distress, discomfort, or injury to persons on adjacent property or interferes with their reasonable use.
- No sign shall duplicate the colors, characteristics, or symbols of traffic signs/signals, or otherwise create confusion for drivers.
- No sign shall be structurally altered to prolong its life or change shape/size or type if nonconforming.
- No sign shall be re-established after damage/destruction exceeding 25% (or 50%, see nonconformance provisions) of replacement cost without compliance.
- Lighting and electronics shall not be added to nonconforming signs, unless approved by site plan.
Exempt Signs in Hurst
- Government-owned traffic signals and markings, and any sign required by law, are exempt.
- The following signs are exempt from permitting (although they must comply with regulations): public notice or warning signs required by law, signs located inside a building not visible from outside, works of art without commercial messages, utility/safety signs not exceeding 1 sq. ft., railway property signs referencing railway operation, security warning or neighborhood watch signs under 2 sq. ft., on-premises residential real estate signs, political signs, and garage sale signs.
- Residential real estate signs, garage sale signs, and political signs do not require a permit if compliant with criteria outlined in the section.
- Gasoline price-per-gallon or credit card signs mounted on pump islands do not require a permit, but must comply with size and placement regulations.
- No permit is required for U.S., Texas, or City of Hurst flags, or for pennants used in grand opening signage, or for window signs inside the glass, or advertising on benches at transit stops.
- Charity/civic event signs do not require a permit fee.
- Bench signs do not require a permit if installed at designated public transportation stops.
Sign Plan & Submission Notes for Hurst
- A planned development (PD) site plan is required for approval of any sign that varies from the strict application of the sign regulations (e.g., signs in public right-of-way, modifications to sign standards, special exceptions, sign variance).
- All new (or renovated/reconstructed) developments within the Town Center District require site plan approval (Sec. 27-15.2(i)).
- All development sites within the Town Center District must be submitted, reviewed, and approved as planned developments in accordance with section 27-16. Any planned development created within the TC district must adhere to regulations unless otherwise stipulated by the PD ordinance.
- A site plan is required prior to construction/reconstruction of any development in districts requiring one (including all mixed-use and PD/overlay districts).
- A landscape plan, including sign location, size, height, orientation, and design, must be included with site plan review for certain zoning districts (see, e.g., RH Retirement Housing, AL Assisted Living, TX 10 Highway and Town Center districts).
- All uses within the RH Retirement Housing and AL Assisted Living districts require site plan approval, which must include the location, size, height, orientation, and design of all signs.
- A certificate of site plan approval is required prior to the issuance of any building permit for alterations, additions, or new signage on Historic Landmark properties (Sec. 27-15.3(e)).
- In Mixed-Use (MU) Planned Development Overlay District, a site plan is required for all PD or SPUD properties; non-mixed-use proposals or single-use building projects must submit for a conditional use permit and request modifications via the site plan process.
- A master sign plan or specific signage details may be a requirement of a planned development site plan whenever signage deviates from base district requirements.
- Sign variances or special exceptions may only be granted after a public hearing by the zoning board of adjustment; an application and site plan are typically required for such cases.
Source: municode municipal code