Union Grove, Wisconsin has specific sign regulations covering 13 sign types across 8 zoning districts. Regulated sign types include Sandwich Board Sign, Temporary Sign or Banner (With Permit - Non-Residential), Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: December 10, 2025
Sign Regulation Overview for Union Grove, Wisconsin
Sample Sign Requirements in Union Grove
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Temporary Sign or Banner (With Permit) | 6 feet (for freestanding ground sign) | 16 square feet in residential districts or 32 square feet in all other districts | Must comply with vision clearance and general setbacks |
| Sandwich Board Sign | 4 feet | — | Outside public right-of-way; vision clearance |
| Subdivision/Development Identification Sign | 10 feet above surrounding grade | — | Outside public right-of-way; vision clearance |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
13
- Sandwich Board Sign
- Temporary Sign or Banner (With Permit - Non-Residential)
- Wall Sign
- Projecting Sign
- +2 more types
Zoning Districts
8
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Union Grove
Other Cities in Wisconsin
Frequently Asked Questions
Sign height limits in Union Grove vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.
To get a sign permit in Union Grove, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Union Grove, regulated sign types include Sandwich Board Sign, Temporary Sign or Banner (With Permit - Non-Residential), Wall Sign, Projecting Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Union Grove vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Union Grove are regulated with specific requirements for brightness, animation, and message duration. Union Grove has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Union Grove Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Union Grove, Wisconsin sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Union Grove, Wisconsin Sign Rules at a Glance
Union Grove, Wisconsin regulates 13 sign types across 8 zoning districts. Ground Sign (At Street Property Line)s in the Commercial Districts (C-1, C-2, C-3) zoning district are capped at 15 feet above mean centerline grade of nearest street tall and 32 square feet per side, with a At street property line; not closer than 150 feet to another ground sign, projecting sign or billboard setback (Sec. Sec. 118-1116(c)). Most commercial signs in Union Grove require a permit.
Detailed Sign Ordinance Requirements for Union Grove, Wisconsin
Sign Rules by Zoning District in Union Grove (8 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 2 | 6 feet (for freestanding ground sign) | 16 square feet in residential districts or 32 square feet in all other districts | — |
| Residential Districts (RS-90, RS-80, RD-90, RD-80, RM, MH) | 2 | 10 feet above surrounding grade | 16 square feet | — |
| Commercial Districts (C-1, C-2, C-3) | 9 | 25 feet | 200 square feet | — |
| Industrial Districts (I-1, I-2) | 9 | 25 feet | 200 square feet | — |
| Park and Conservancy District (PC) | 7 | 20 feet above adjacent centerline street grade | 200 square feet | — |
| Institutional District (P-1) | 7 | 20 feet above adjacent centerline street grade | 200 square feet | — |
| Agricultural District (A) | 1 | 6 feet (for freestanding) | 32 square feet | — |
| Planned Unit Development Overlay District (PUD) | 1 | 6 feet (for freestanding) | 32 square feet | — |
Zone-by-Zone Sign Requirements in Union Grove(sample of 3 of 8 zones)
Commercial Districts (C-1, C-2, C-3)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | — | 200 square feet | — | Outside public right-of-way | — | On or against exterior wall(s) of building; not above ceiling level of top floor; not blocking windows, doors or vents | — | Unlock | Sec. 118-1116(a) |
| Projecting Sign | 20 feet above adjacent centerline street grade | 25 square feet per tenant; 150 square feet per premises | — | Not project more than 36 inches into public ROW; 10 feet from side lot lines | — | Fastened to, suspended from or supported by building; not less than 10 feet from side lot lines or beyond building wall | — | Unlock | Sec. 118-1116(b) |
| Ground Sign (At Street Property Line) | 15 feet above mean centerline grade of nearest street | 32 square feet per side | — | At street property line; not closer than 150 feet to another ground sign, projecting sign or billboard | One per street frontage | Freestanding on property | — | Unlock | Sec. 118-1116(c) |
| Ground Sign (Set Back 5 Feet or More) | 15 feet above mean centerline grade of nearest street | 40 square feet per side | — | At least 5 feet from street property line; not closer than 150 feet to another ground sign, projecting sign or billboard | One per street frontage | Freestanding on property | — | Unlock | Sec. 118-1116(c) |
| Off-Premise Directional/Sales Sign | — | 50 square feet per side | — | As per formula; comply with district setbacks | Not to exceed 2 per business within village | In retail business or industrial zoning district; maximum 5 miles from advertised business | — | Unlock | Sec. 118-1116(d) |
| Billboard | 25 feet | — | — | Same as principal buildings in district; not closer than 1,320 feet to another billboard, ground sign or off-premise sign | — | In retail business or industrial zoned areas | — | Unlock | Sec. 118-1116(f) |
| Sandwich Board Sign | 4 feet | — | 2 feet | Outside ROW; vision clearance | 1 per business | Adjacent to business; during business hours only | — | Unlock | Sec. 118-1116(i) |
| Temporary Sign or Banner (With Permit - Non-Residential) | 6 feet (for freestanding) | 32 square feet | — | General setbacks | One per frontage | Attached or freestanding on property | — | Unlock | Sec. 118-1114(a) |
Industrial Districts (I-1, I-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | — | 200 square feet | — | Outside public right-of-way | — | On or against exterior wall(s) of building; not above ceiling level of top floor; not blocking windows, doors or vents | — | Unlock | Sec. 118-1116(a) |
| Projecting Sign | 20 feet above adjacent centerline street grade | 25 square feet per tenant; 150 square feet per premises | — | Not project more than 36 inches into public ROW; 10 feet from side lot lines | — | Fastened to, suspended from or supported by building; not less than 10 feet from side lot lines or beyond building wall | — | Unlock | Sec. 118-1116(b) |
| Ground Sign (At Street Property Line) | 15 feet above mean centerline grade of nearest street | 32 square feet per side | — | At street property line; not closer than 150 feet to another ground sign, projecting sign or billboard | One per street frontage | Freestanding on property | — | Unlock | Sec. 118-1116(c) |
| Ground Sign (Set Back 5 Feet or More) | 15 feet above mean centerline grade of nearest street | 40 square feet per side | — | At least 5 feet from street property line; not closer than 150 feet to another ground sign, projecting sign or billboard | One per street frontage | Freestanding on property | — | Unlock | Sec. 118-1116(c) |
| Off-Premise Directional/Sales Sign | — | 50 square feet per side | — | As per formula; comply with district setbacks | Not to exceed 2 per business within village | In retail business or industrial zoning district; maximum 5 miles from advertised business | — | Unlock | Sec. 118-1116(d) |
| Billboard | 25 feet | — | — | Same as principal buildings in district; not closer than 1,320 feet to another billboard, ground sign or off-premise sign | — | In retail business or industrial zoned areas | — | Unlock | Sec. 118-1116(f) |
| Sandwich Board Sign | 4 feet | — | 2 feet | Outside ROW; vision clearance | 1 per business | Adjacent to business; during business hours only | — | Unlock | Sec. 118-1116(i) |
| Temporary Sign or Banner (With Permit - Non-Residential) | 6 feet (for freestanding) | 32 square feet | — | General setbacks | One per frontage | Attached or freestanding on property | — | Unlock | Sec. 118-1114(a) |
Park and Conservancy District (PC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | — | 200 square feet | — | Outside public right-of-way | — | On or against exterior wall(s) of building; not above ceiling level of top floor; not blocking windows, doors or vents | — | Unlock | Sec. 118-1116(a) |
| Projecting Sign | 20 feet above adjacent centerline street grade | 25 square feet per tenant; 150 square feet per premises | — | Not project more than 36 inches into public ROW; 10 feet from side lot lines | — | Fastened to, suspended from or supported by building; not less than 10 feet from side lot lines or beyond building wall | — | Unlock | Sec. 118-1116(b) |
| Ground Sign (At Street Property Line) | 15 feet above mean centerline grade of nearest street | 32 square feet per side | — | At street property line; not closer than 150 feet to another ground sign, projecting sign or billboard | One per street frontage | Freestanding on property | — | Unlock | Sec. 118-1116(c) |
| Ground Sign (Set Back 5 Feet or More) | 15 feet above mean centerline grade of nearest street | 40 square feet per side | — | At least 5 feet from street property line; not closer than 150 feet to another ground sign, projecting sign or billboard | One per street frontage | Freestanding on property | — | Unlock | Sec. 118-1116(c) |
| Window Sign (Permanent) | — | 50 percent of window glass area (100 percent for perforated decals) | — | — | — | Inside the window or on window surface | — | Unlock | Sec. 118-1116(e) |
| Sandwich Board Sign | 4 feet | — | 2 feet | Outside ROW; vision clearance | 1 per business | Adjacent to business; during business hours only | — | Unlock | Sec. 118-1116(i) |
| Temporary Sign or Banner (With Permit - Conservancy/Floodplain) | 6 feet (for freestanding) | 16 square feet in residential or 32 square feet in other (applies 32 sq ft) | — | General setbacks; outside floodplain restrictions if applicable | One per frontage | Attached or freestanding on property in upland/lowland areas | — | Unlock | Sec. 118-1118 |
PermitPal covers all 8 zoning districts in Union Grove — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 8 zones for Union Grove — start freeProhibited Signs in Union Grove
- It shall be unlawful to locate, erect, move, reconstruct, extend, enlarge, convert, or structurally alter any sign without complying with the requirements of this article or applicable state or federal requirements.
- Signs on rooftops are prohibited.
- Flashing, blinking, or electronically movable copy (scrolling) signs are prohibited.
- Portable and other movable signs are prohibited.
- Any sign within a public street or highway right-of-way is prohibited without written permission of the public body having jurisdiction.
- No sign may be located within a vision triangle of two or more intersecting streets without written permission.
- Signs shall not resemble, imitate, or approximate the shape, size, form, or color of railroad or traffic signs, signals, or devices.
- Signs shall not be erected, relocated, or maintained so as to prevent free ingress to or egress from any door, window, or fire escape.
- No sign shall be attached to a standpipe or fire escape.
- Signs shall be placed so as not to obstruct or interfere with traffic visibility.
Exempt Signs in Union Grove
- Temporary signs permitted without a permit, including one sign up to 4 square feet at any time, one small window sign (8.5x11 inches), limited to 7 days per month; real estate signs with owner consent for sale properties; election campaign signs per Wisconsin Statutes §12.04 with size limits; rummage/garage/estate sale signs complying with temporary requirements.
- Government signs erected, maintained, or posted by federal, state, local government, or special purpose units like utility or school districts.
- Required signs posted to comply with federal, state, or local law warning of danger or prohibiting access.
- Building monument signs carved into or affixed flat to a building, not directly illuminated, non-reflective, low contrast, not exceeding 2 inches in thickness.
- Signs not visible from any public street, highway, sidewalk, or bicycle path.
Sign Plan & Submission Notes for Union Grove
- Permanent structures identifying a subdivision/development require review and approval by the plan commission prior to permit issuance.
- Permanent ground signage structures on parcels over 5 acres, exceeding 40 square feet, or any changes require approval by the plan commission.
- Off-premise directional/sales signs and billboards require permission by the plan commission.
- Multiple projecting signs on one premises serving multiple tenants require design approval by the plan commission.
- Electronic signs displaying messages beyond time/temperature require approval by the plan commission.
- Neon signs or exterior neon displays require approval by the plan commission to complement architectural design.
- Exceptions to area, height, and setback requirements may be granted upon approval by the plan commission after review of detailed site plans and sign details.
- Aesthetic appearance, lighting, and landscaping of permanent signs must be approved by the plan commission; in downtown districts, also by the CDA.
- The building inspector may direct applicants to meet with the plan commission for review and guidance on permit issuance or standards interpretation.
- Signs in downtown districts must comply with downtown design guidelines and be approved by the CDA and plan commission.
Source: other municipal code