Questions? Call us at (262) 218-2915

Sign Regulations in Evans, Colorado

Evans, Colorado has specific sign regulations covering 31 sign types across 4 zoning districts. Regulated sign types include Wall Sign, Freestanding Sign, Gateway Sign (Residential). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 7, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Evans, Colorado

Sample Sign Requirements in Evans

Sign TypeMax HeightMax AreaSetback
Wall SignNot listed50 sq ft per signNot listed
Freestanding Sign6 ft32 sq ft10' from flow line and on private property (whichever greater)
Gateway Sign (Residential)6 ft24 sq ft for entrances on collector; 48 sq ft for entrances on arterial10' from lot/parcel line or at least the same as its height (whichever is greater)

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for EvansFull Coverage

Sign Types Covered

31

  • Wall Sign
  • Freestanding Sign
  • Gateway Sign (Residential)
  • Temporary Sign (Lots < 100' frontage)
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Evans

City WebsiteMunicipal Code3 permit application links available

Frequently Asked Questions

In Evans, the height limit for Freestanding Sign (Local Street) in certain zoning districts is 12 ft generally. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Evans require a permit. From the submission notes on this page: A permit application is generally required for all signs unless specifically exempted by 18.09.040 or for maintenance/change of copy as described. Run a code check for an exact address to see the permit requirements for that zone.

Evans's sign code covers 31 sign types, including Wall Sign, Freestanding Sign, Gateway Sign (Residential), and Temporary Sign (Lots < 100' frontage). Most commercial signs need a permit. The ordinance lists 14 exemptions. One of them: Signs exempt from permit process as specified in 18.09.040. The full list is on this page.

In Evans, Incidental Sign must be set back 10' from all property lines (Sec. 18.09.040.F). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Evans's sign ordinance that cover digital, changing, or flashing signs: No sign shall include balloons, streamers, pennants, air-activated elements, or animated elements (mechanical, electrical, or environmental). Changeable copy portions are limited to thirty-two (32) square feet and to one sign per business or institution (except as provided for electronic message centers). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Evans Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Evans, Colorado, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Evans, Colorado Sign Rules at a Glance

Evans, Colorado regulates 31 sign types across 4 zoning districts. Gateway Signs (Non-residential) in certain zoning districts are capped at 16 ft tall and 200 sq ft per sign (Sec. 18.09.080.F.1). Most commercial signs in Evans require a permit.

Detailed Sign Ordinance Requirements for Evans, Colorado

Sign Rules by Zoning District in Evans (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential Zoning Districts (AG, R1E, R1, R2, R3, R, MFH, RMH)76 ft50 sq ft per signNot listed
Non-residential Zoning Districts (PF, C1, C2, C3, I1, I2, I3, 85-O, 85-RC-A, 85-RC-N, 85-RC-R)1516 ft200 sq ft per signNot listed
Planned Unit Developments (PUDs)1Not listedNot listedNot listed
General Regulations For All Zones812 ft (building); 36 in (ground)100 sq ft per flag, 200 sq ft totalNot listed

Zone-by-Zone Sign Requirements in Evans(sample of 3 of 4 zones)

Residential Zoning Districts (AG, R1E, R1, R2, R3, R, MFH, RMH)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignNot listed50 sq ft per signNot listedNot listed2 per building, max 1 per wallOn building walls for permitted principal non-residential or multi-family uses (school, church, community center, apartments)Not listedUnlockTable 18.09-1; 18.09.050.B
Freestanding Sign6 ft32 sq ftNot listed10' from flow line and on private property (whichever greater)1 per street frontage over 100' of frontageOn private property for permitted principal non-residential or multi-family uses; must be 10' from flow line and on private property (whichever greater)Not listedUnlockTable 18.09-1; 18.09.050.B
Gateway Sign (Residential)6 ft24 sq ft for entrances on collector; 48 sq ft for entrances on arterialNot listed10' from lot/parcel line or at least the same as its height (whichever is greater)2 per entrance from collector or arterial streetOn site of residential use or in common area controlled by property/homeowner's associationNot listedUnlock18.09.080.F.2
Temporary Sign (Lots < 100' frontage)5 ft (ground); 20 ft or top of roof for building-mounted9 sq ft per signNot listedNot listedNot listedNot listedNot listedUnlockTable 18.09-1; 18.09.050.B; 18.09.080.C
Temporary Sign (Lots with 100' - 200' frontage)5 ft (ground); 20 ft or top of roof for building-mounted16 sq ft per signNot listedNot listedNot listedNot listedNot listedUnlockTable 18.09-1; 18.09.050.B; 18.09.080.C
Temporary Sign (Lots > 200' frontage)5 ft (ground); 20 ft or top of roof for building-mounted24 sq ft per signNot listedNot listedNot listedNot listedNot listedUnlockTable 18.09-1; 18.09.050.B; 18.09.080.C
Pedestrian Sign5 ft12 sq ftNot listedNot listed1 per public entranceMounted on wall within 10' of entrance or on ground within 20' of entrance. For permitted principal non-residential or multi-family uses.Not listedUnlockTable 18.09-1; 18.09.050.B

Non-residential Zoning Districts (PF, C1, C2, C3, I1, I2, I3, 85-O, 85-RC-A, 85-RC-N, 85-RC-R)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Local Street)No taller than the wall (flat roof) or roof deck/eave line (pitched roof)200 sq ft per signNot listedNot listed1 per wall, plus up to 3 accessory signsOn building wall with primary building frontage along a local streetNot listedUnlockTable 18.09-2; 18.09.060.B
Wall Sign (Collector)No taller than the wall (flat roof) or roof deck/eave line (pitched roof)200 sq ft per signNot listedNot listed1 per wall, plus up to 3 accessory signsOn building wall with primary building frontage along a collector streetNot listedUnlockTable 18.09-2; 18.09.060.B
Wall Sign (Arterial/Highway/Frontage)No taller than the wall (flat roof) or roof deck/eave line (pitched roof)200 sq ft per signNot listedNot listed1 per wall, plus up to 3 accessory signsOn building wall with primary building frontage along an arterial, highway or frontage roadNot listedUnlockTable 18.09-2; 18.09.060.B
Freestanding Sign (Local Street)12 ft generally125 sq ft per signNot listed10' from flow line and on private property (whichever greater)Not listedOn private property; set back 10' from flow line and on private property (whichever greater)Not listedUnlockTable 18.09-2; 18.09.060.B
Freestanding Sign (Collector)12 ft generally125 sq ft per signNot listed10' from flow line and on private property (whichever greater)Not listedOn private property; set back 10' from flow line and on private property (whichever greater)Not listedUnlockTable 18.09-2; 18.09.060.B
Freestanding Sign (Arterial)12 ft generally125 sq ft per signNot listed10' from flow line and on private property (whichever greater)Not listedOn private property; set back 10' from flow line and on private property (whichever greater)Not listedUnlockTable 18.09-2; 18.09.060.B
Freestanding Sign (Highway/Frontage Road)12 ft; up to 16 ft if setback at least 16 ft; up to 25 ft if abutting US Highway/West Service Road/8th Ave; up to 35 ft if setback at least 35 ft and abutting US Highway/West Service Road/8th Ave125 sq ft per signNot listed10' from flow line and on private property (whichever greater), plus setbacks per height conditions.Not listedOn private property; set back 10' from flow line and on private property (whichever greater)Not listedUnlockTable 18.09-2; 18.09.060.B
Gateway Sign (Non-residential)16 ft200 sq ft per signNot listed10' or same as height from lot/parcel line, whichever greater1 per entrance and 1 per street intersectionOn site of non-residential use or in common area owned by property/business associationNot listedUnlock18.09.080.F.1

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Address Sign12 ft (building); 36 in (ground)2 sq ft per signNot listedNot listed2 per address, max 1 ground-mountedBuilding-mounted or on ground (1 only); must be visible from right-of-wayNot listedUnlock18.09.040.A.1
Building Name Plate SignNot listed9 sq ftNot listedNot listed1 per building/site per street frontAssociated with building/site, not a particular tenantNot listedUnlock18.09.040.A.2
Flag (Residential)Subject to zoning district height limit40 sq ft per flag, 80 sq ft totalNot listedIf on pole: setback equal to actual pole height3 per lotMounted to building (below height) or pole (setback equal to pole height)Not listedUnlock18.09.040.C
Flag (Non-residential)Subject to zoning district height limit100 sq ft per flag, 200 sq ft totalNot listedIf on pole: setback equal to actual pole height3 per lotMounted to building (below height) or pole (setback equal to pole height)Not listedUnlock18.09.040.C
Window Sign (Non-residential districts)Not listed25% of all first floor windowsNot listedNot listedNot listedMounted inside first floor windows in non-residential districtsNot listedUnlock18.09.040.D
Incidental Sign6 ft if ground mounted, 12 ft if building mounted3 sq ft per sign (9 sq ft per sign for lots >1 acre)Not listed10' from all property linesBased on size limitations (see formula)On-site onlyNot listedUnlock18.09.040.F
Construction Sign (Non-residential or multi-family)10 ft (ground mounted)80 sq ft per frontage (total)Not listedNot listedUp to 3 per street frontageMounted on trailer, building, fence, or on groundNot listedUnlock18.09.040.G
Interior Sign (not visible from right-of-way/adjacent property/publicly accessible spaces)Not listedNot listedNot listedNot listedNot listedInside, not visible from right-of-way or adjacent propertyNot listedUnlock18.09.040.H

PermitPal covers all 4 zoning districts in Evans. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Evans

  • All signs must be designed, constructed, located, and maintained in compliance with building and fire codes and must not pose a risk to public safety as judged by the Building Official, Fire Chief, or Community Development Director.
  • No sign shall imitate or resemble government signs for traffic direction or any other public safety symbol.
  • No sign shall be placed in any sight distance triangle applicable to public streets, internal access streets, or driveway access points per the sight distance provisions of Section 15.58 Sight Distance of the Municipal Code.
  • No sign shall be placed within five (5) feet of a fire hydrant.
  • Any sign projecting over a walkway or active area must maintain at least seven (7) feet six (6) inches of vertical clearance.
  • All signs and surrounding grounds must be maintained in good condition, free of debris, weeds, disrepair, or unsightly conditions.
  • No sign, sign structure, or grounds may be in a dilapidated condition or have property maintenance issues affecting appearance from the public right-of-way or adjacent property.
  • No sign shall be placed on vehicles or trailers parked visible from the right-of-way if the sign deviates from the ordinance standards.
  • No sign shall be attached to any public utility pole or installed within the right-of-way of a public road or street, except as specifically permitted.
  • No sign shall include balloons, streamers, pennants, air-activated elements, or animated elements (mechanical, electrical, or environmental).
  • Any sign with a business message must be located on the lot of the business, except gateway signs, which must be in common areas controlled by businesses/property owners associations.
  • Changeable copy portions are limited to thirty-two (32) square feet and to one sign per business or institution (except as provided for electronic message centers).
  • Illumination of signs must not result in direct light sources visible from the street or adjacent residential properties.
  • External light sources must be shielded to prevent illumination of objects other than the sign.
  • Illumination from a sign must not spill onto adjacent properties and must be less than one (1) foot-candle within ten (10) feet from adjacent property.
  • No light source shall create glare, movement, or other traffic distractions.
  • Exposed incandescent, neon, or tube lighting is limited to window signs inside buildings, or as an accent up to 10% of sign area for other signs.
  • Signs within 100 feet and visible from single-family or two-family residential properties must not be internally or directly illuminated between 10:00 p.m. and 6:00 a.m.
  • Signs may not project over driveways, parking areas below fourteen (14) feet above grade, or pedestrian ways below eight (8) feet above grade.
  • Signs or sign structures shall not project into public rights-of-way or alleys, or within two (2) feet of a curb line.
  • Signs cannot obstruct openings in buildings so as to reduce required light or ventilation.

Exempt Signs in Evans

  • Legal non-conforming signs as subject to other code provisions.
  • Signs exempt from permit process as specified in 18.09.040.
  • Property identification signs that clearly indicate address or building identification and meet specified limitations.
  • Address signs (two per address, size & mounting and visibility limits).
  • Building name plate signs (one per building/site per street front, up to nine (9) square feet, associated with building permanence or significance).
  • Public safety, traffic control, or public information signs required by law or to support official government actions.
  • Up to three (3) non-commercial flags per lot, within area/mounting limits.
  • Window signs mounted to the interior of first-floor windows in non-residential districts, within percentage/visibility limits.
  • Temporary signs that are within the allowances for the zone/district.
  • Incidental signs for non-residential uses or multi-family complexes, within area, height, and location limits, not grouped to increase allowance or visibility to the general public.
  • Construction signs associated with temporary non-residential or multi-family construction projects under a valid permit, meeting area, quantity, height, and duration limits.
  • Interior signs not visible from public right-of-way, property perimeter, adjacent property, or publicly accessible common spaces (except as required by building or fire code).
  • Ordinary maintenance, care, or repair of existing conforming signs, without altering size, materials, location, or other essential elements.
  • Change of copy or content or sign panels on existing conforming signs, provided no changes are made to size, materials, structure, or essential characteristics.

Sign Plan & Submission Notes for Evans

  • A Sign Plan and Permit approved by the Community Development Director (or designee) is required for all multi-tenant buildings or sites.
  • The sign plan for multi-tenant sites must demonstrate coordination of all signs, allow flexibility for tenant change (unless there is a new design concept for the entire site), and be apportioned per ordinance rules.
  • Deviations from specific design standards may be approved only through a Comprehensive Sign Plan as specified in Section 18.09.090.
  • A Comprehensive Sign Plan may be proposed for shopping centers, office parks, or other multi-tenant non-residential projects with four or more buildings or five or more acres, or any PUD zoning.
  • A permit application is generally required for all signs unless specifically exempted by 18.09.040 or for maintenance/change of copy as described.
  • Master or comprehensive sign plans must be authorized by the property owner/landlord and require Planning Commission or City Council approval for deviations.
  • For gateway signs in non-residential projects, a Comprehensive Sign Plan is required to allocate freestanding sign allowance to gateway signs.

Source: municode municipal code