Sign Regulations in Richfield, Ohio

Richfield, Ohio has specific sign regulations covering 11 sign types across 4 zoning districts. Regulated sign types include Sign Plate, Temporary Sign, General Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 11, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Richfield, Ohio

Sample Sign Requirements in Richfield

Sign TypeMax HeightMax AreaSetback
Sign PlateNot listed2 sfNot listed
Ground Sign for Use/Development5 ft40 sf25 ft
Wall SignNot listed40 sfNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for RichfieldFull Coverage

Sign Types Covered

11

  • Sign Plate
  • Temporary Sign
  • General Sign
  • Ground Sign for Use/Development
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Richfield

Frequently Asked Questions

In Richfield, the height limit for Ground Sign in the Commercial District and other zoning districts is 6 ft (Sec. 1163.17(e)). Maximum sign heights range from 8 ft to 14 ft across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Richfield require a permit. From the submission notes on this page: The Commission shall review and act on applications for permanent signs according to the standards set forth in this Section and the review procedures for development plan review set forth in Chapter 1171. Run a code check for an exact address to see the permit requirements for that zone.

Richfield's sign code covers 11 sign types, including Sign Plate, Temporary Sign, General Sign, and Ground Sign for Use/Development. Most commercial signs need a permit. The ordinance lists 2 exemptions. One of them: Architectural features that are either part of the building or part of a freestanding structure are not considered signs but shall conform to Section 1163.17(e). The full list is on this page.

In Richfield, Ground Sign for Use/Development in the Residential District must be set back 25 ft (Sec. 1163.15(a)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Richfield's sign ordinance that cover digital, changing, or flashing signs: Electronic reader boards. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Richfield Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Richfield, Ohio, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Richfield, Ohio Sign Rules at a Glance

Richfield, Ohio regulates 11 sign types across 4 zoning districts. Banners in the Residential District are capped at 8 ft tall and 30 sq ft, with a 25 ft setback (Sec. 1163.15(a)). Most commercial signs in Richfield require a permit.

Detailed Sign Ordinance Requirements for Richfield, Ohio

Sign Rules by Zoning District in Richfield (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential District68 ft40 sfNot listed
Commercial District, Industrial District, CH-I, CH-II, C-1, C-2, C-3, PCD, OL, OLI, I614 ft50 sf (CH-I, CH-II, C-1)Not listed
C-H Historic Commercial District1Not listedNot listedNot listed
General Regulations For All Zones1Not listedNot listedNot listed

Zone-by-Zone Sign Requirements in Richfield(sample of 3 of 4 zones)

Residential District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Sign PlateNot listed2 sfNot listedNot listed1/duWall, Window or GroundNot listedUnlock1163.15(a)
Ground Sign for Use/Development5 ft40 sfNot listed25 ft1/entrance1/entranceNot listedUnlock1163.15(a)
Wall SignNot listed40 sfNot listedNot listed1Non-ResidentialNot listedUnlock1163.15(a)
Temporary Sign5 ft8 sf/duNot listed0 ftNot listedWindow or GroundNot listedUnlock1163.15(a)
Banner8 ft30 sfNot listed25 ft1Multifamily, Non-ResidentialNot listedUnlock1163.15(a)
Instructional SignNot listed4 sfNot listed0 ft2/entranceMultifamily, Non-ResidentialNot listedUnlock1163.15(a)

Commercial District, Industrial District, CH-I, CH-II, C-1, C-2, C-3, PCD, OL, OLI, I

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Sign PlateNot listed2 sfNot listedNot listed1Per addressNot listedUnlock1163.17(a)
Building SignNot listed50 sf (CH-I, CH-II, C-1)Not listedNot listed1Per occupantNot listedUnlock1163.17(a)
Projecting Sign14 ft12 sfNot listedNot listed1/buildingCH-I, CH-II, C-1Not listedUnlock1163.17(d)
Ground Sign6 ft25 sf (CH-I, CH-II, C-1)Not listed15 ft (CH-I, CH-II, C-1)1Per buildingNot listedUnlock1163.17(e)
Entrance/Exit SignNot listed2 sf (CH-I, CH-II, C-1)Not listedNot listed2/drivePer driveNot listedUnlock1163.17(e)
Temporary Sign6 ft6 sfNot listed15 ft1Ground, Window, A-frame, BannerNot listedUnlock1163.17(f)

C-H Historic Commercial District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
General SignNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlock1145.11

PermitPal covers all 4 zoning districts in Richfield. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Richfield

  • Roof signs.
  • Billboards.
  • Flags intended for advertising or commercial purposes.
  • Marquee signs.
  • Electronic reader boards.
  • No mobile signs shall be erected, constructed, displayed or maintained except those on licensed commercial delivery and service vehicles.
  • Temporary directional signs.
  • Flashing, moving, inflatable, blinker, racer type, intermittent, rotating, moving or revolving signs, whirligig devices, inflatable signs and tethered balloons, pennants, ribbons, streamers, spinners, exposed light bulbs, and strings of lights not permanently mounted to a rigid background, and other similar types of attention-getting devices.
  • The interior illumination of signs, except as expressly permitted in Section 1163.21(a) and signs with characters, letters, figures, designs or outlines by electric lights or luminous tubes as part of the sign.
  • Merchandise, equipment, products, vehicles or other items not themselves for sale and placed for attention getting, identification, or advertising purposes.
  • Permanent sign erected or attached to accessory structures.
  • Outline lighting of the building or roofline.
  • Internal illumination of all or part of the roof.

Exempt Signs in Richfield

  • Architectural features that are either part of the building or part of a freestanding structure are not considered signs but shall conform to Section 1163.17(e).
  • The erection of the following signs shall not require a zoning certificate provided that all applicable regulations of this Section are complied with: Signplates for residential uses, Temporary signs for dwelling units, Temporary window signs, Maintenance of existing signs in compliance with Section 1163.21(c).

Sign Plan & Submission Notes for Richfield

  • Owners of multi-tenant buildings shall develop a sign plan for the building and site as required in Chapter 1171 to aid in determining the level of variety or cohesiveness required for signs.
  • The Commission shall review and act on applications for permanent signs according to the standards set forth in this Section and the review procedures for development plan review set forth in Chapter 1171.

Source: amlegal municipal code